2013•Unpublished venueRequires access

Determination of eight ginsenosides in Renshenshouwu capsules by HPLC-DAD

Ji Lin

Open publisher page 0 citations

Abstract

Objective: To establish an HPLC-DAD method for simultaneous determination of eight ginsenosides in Renshenshouwu capsules.Method: Ultimate C 18 column(4.6 mm × 250 mm,5 μm) was adopted for gradient elution,with acetonitrile and water as the mobile phase.The flow rate was 1 mL·min-1,the column temperature was set at 30 ℃,and the detection wavelength was 203 nm.Result: A good linearity was observed in the range of 0.242-12.1,0.222-11.1,0.251-25.1,0.245-24.5,0.23223.2,0.232-23.2,0.264-26.4,0.244-24.4 μg for ginsenoside Rg 1,Re,Rb 1,Rc,Rb 2,Rb 3,Rd and 20(S)-ginsenoside Rg 3,respectively,with the average recoveries of 102.7%,103.2%,101.6%,101.2%,102.0%,100.7%,101.9%,102.0%,respectively.Conclusion: The method was so simple,accurate and effective that it could be used for quality control of the above eight components in Renshenshouwu capsules.

About this research paper

What this paper is about

Objective: To establish an HPLC-DAD method for simultaneous determination of eight ginsenosides in Renshenshouwu capsules.Method: Ultimate C 18 column(4.6 mm × 250 mm,5 μm) was adopted for gradient elution,with acetonitrile and water as the mobile phase.The flow rate was 1 mL·min-1,the column temperature was set at 30 ℃,and the detection wavelength was 203 nm.Result: A good linearity was observed in the range of 0.242-12.1,0.222-11.1,0.251-25.1,0.245-24.5,0.23223.2,0.232-23.2,0.264-26.4,0.244-24.4 μg for ginsenoside Rg 1,Re,Rb 1,Rc,Rb 2,Rb 3,Rd and 20(S)-ginsenoside Rg 3,respectively,with the average recoveries of 102.7%,103.2%,101.6%,101.2%,102.0%,100.7%,101.9%,102.0%,respectively.Conclusion: The method was so simple,accurate and effective that it could be used for quality control of the above eight components in Renshenshouwu capsules.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To establish an HPLC-DAD method for simultaneous determination of eight ginsenosides in Renshenshouwu capsules.Method: Ultimate C 18 column(4.6 mm × 250 mm,5 μm) was adopted for gradient elution,with acetonitrile and water as the mobile phase.The flow rate was 1 mL·min-1,the column temperature was set at 30 ℃,and the detection wavelength was 203 nm.Result: A good linearity was observed in the range of 0.242-12.1,0.222-11.1,0.251-25.1,0.245-24.5,0.23223.2,0.232-23.2,0.264-26.4,0.244-24.4 μg for ginsenoside Rg 1,Re,Rb 1,Rc,Rb 2,Rb 3,Rd and 20(S)-ginsenoside Rg 3,respectively,with the average recoveries of 102.7%,103.2%,101.6%,101.2%,102.0%,100.7%,101.9%,102.0%,respectively.Conclusion: The method was so simple,accurate and effective that it could be used for quality control of the above eight components in Renshenshouwu capsules.

Key concepts: Chromatography, Chemistry, Ginsenoside, Gradient elution, High-performance liquid chromatography, Acetonitrile, Ginsenoside Rg1, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of eight ginsenosides in Renshenshouwu capsules by HPLC-DAD — Research Paper | ScholarLens