2013•China Journal of Chinese Materia MedicaRequires access

Determination of eight ginsenosides in Renshenshouwu capsules by HPLC-DAD

Li-Na Ji, Wei-Hong Feng, Zhimin Wang, Jing-Jing Zhu, Qi-Wei Zhang, Liang‐Mian Chen, Chun Li

Open publisher page 0 citations

Abstract

OBJECTIVE: To establish an HPLC-DAD method for simultaneous determination of eight ginsenosides in Renshenshouwu capsules. METHOD: Ultimate C18 column (4.6 mm x 250 mm, 5 microm) was adopted for gradient elution, with acetonitrile and water as the mobile phase. The flow rate was 1 mL x min(-1), the column temperature was set at 30 degrees C, and the detection wavelength was 203 nm. RESULT: A good linearity was observed in the range of 0.242-12.1, 0.222-11.1, 0.251-25.1, 0. 245-24.5, 0.232-23.2, 0.232-23.2, 0.264-26.4, 0.244-24.4 microg for ginsenoside Rg1, Re, Rb1, Rc, Rb2, Rb3, Rd and 20(S)-ginsenoside Rg3, respectively, with the average recoveries of 102.7%, 103.2%, 101.6%, 101.2%, 102.0%, 100.7%, 101.9%, 102.0%, respectively. CONCLUSION: The method was so simple, accurate and effective that it could be used for quality control of the above eight components in Renshenshouwu capsules.

About this research paper

What this paper is about

OBJECTIVE: To establish an HPLC-DAD method for simultaneous determination of eight ginsenosides in Renshenshouwu capsules. METHOD: Ultimate C18 column (4.6 mm x 250 mm, 5 microm) was adopted for gradient elution, with acetonitrile and water as the mobile phase. The flow rate was 1 mL x min(-1), the column temperature was set at 30 degrees C, and the detection wavelength was 203 nm. RESULT: A good linearity was observed in the range of 0.242-12.1, 0.222-11.1, 0.251-25.1, 0. 245-24.5, 0.232-23.2, 0.232-23.2, 0.264-26.4, 0.244-24.4 microg for ginsenoside Rg1, Re, Rb1, Rc, Rb2, Rb3, Rd and 20(S)-ginsenoside Rg3, respectively, with the average recoveries of 102.7%, 103.2%, 101.6%, 101.2%, 102.0%, 100.7%, 101.9%, 102.0%, respectively. CONCLUSION: The method was so simple, accurate and effective that it could be used for quality control of the above eight components in Renshenshouwu capsules.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To establish an HPLC-DAD method for simultaneous determination of eight ginsenosides in Renshenshouwu capsules. METHOD: Ultimate C18 column (4.6 mm x 250 mm, 5 microm) was adopted for gradient elution, with acetonitrile and water as the mobile phase. The flow rate was 1 mL x min(-1), the column temperature was set at 30 degrees C, and the detection wavelength was 203 nm. RESULT: A good linearity was observed in the range of 0.242-12.1, 0.222-11.1, 0.251-25.1, 0. 245-24.5, 0.232-23.2, 0.232-23.2, 0.264-26.4, 0.244-24.4 microg for ginsenoside Rg1, Re, Rb1, Rc, Rb2, Rb3, Rd and 20(S)-ginsenoside Rg3, respectively, with the average recoveries of 102.7%, 103.2%, 101.6%, 101.2%, 102.0%, 100.7%, 101.9%, 102.0%, respectively. CONCLUSION: The method was so simple, accurate and effective that it could be used for quality control of the above eight components in Renshenshouwu capsules.

Key concepts: Chromatography, Chemistry, Ginsenoside Rg1, Ginsenoside, High-performance liquid chromatography, Gradient elution, Acetonitrile, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of eight ginsenosides in Renshenshouwu capsules by HPLC-DAD — Research Paper | ScholarLens