2018•International Journal of Clinical Biochemistry and ResearchOpen access

Use of deproteinizer to eliminate interference of high bilirubin on measurement of serum creatinine by the kinetic jaffe reaction

Vijaysinh Parmar, Hiren Sanghani, Asha Khubchandani

Open full text 0 citations

Abstract

Introduction: Serum creatinine is a useful diagnostic parameter of kidney function. Its concentration reflects glomerular filtration rate. Because of negative interference of bilirubin over creatinine level, may mislead the clinician. The most common and serious problems in the determination of serum creatinine concentration by the kinetic Jaffe method is the negative interference by bilirubin. Materials and Methods: This cross sectional study was done on 160 patients which have high bilirubin level, taken from B. J. Medical College, Civil hospital, Ahmedabad from August 2013 to December 2013. These samples were studied for interference of total bilirubin on measurement of Serum creatinine level before and after treating with deproteinizer (trichloroacetic acid 0.55 mmol/ltr). Serum bilirubin and serum creatinine level were measured by modified Jendrassik & Groff’s method and kinetic Jaffe’s reaction respectively by using Erba XL-640 fully auto analyzer. Results: In this study significant difference was found in Serum Creatinine level with the samples of high bilirubin content before and after treating with deproteinizer (trichloroacetic acid) (pPreprecipitation of albumin along with bilirubin by trichloroacetic acid beforehand is suggested as an approach to correct the bilirubin interference. Conclusion: From this study it is concluded that bilirubin have negative interference on serum creatinine level. And this is corrected by using deproteinizer trichloroacetic acid. Keywords: Serum Creatinine, Serum bilirubin, Negative .intereference

Open-access reader

About this research paper

What this paper is about

Introduction: Serum creatinine is a useful diagnostic parameter of kidney function. Its concentration reflects glomerular filtration rate. Because of negative interference of bilirubin over creatinine level, may mislead the clinician. The most common and serious problems in the determination of serum creatinine concentration by the kinetic Jaffe method is the negative interference by bilirubin. Materials and Methods: This cross sectional study was done on 160 patients which have high bilirubin level, taken from B. J. Medical College, Civil hospital, Ahmedabad from August 2013 to December 2013. These samples were studied for interference of total bilirubin on measurement of Serum creatinine level before and after treating with deproteinizer (trichloroacetic acid 0.55 mmol/ltr). Serum bilirubin and serum creatinine level were measured by modified Jendrassik & Groff’s method and kinetic Jaffe’s reaction respectively by using Erba XL-640 fully auto analyzer. Results: In this study significant difference was found in Serum Creatinine level with the samples of high bilirubin content before and after treating with deproteinizer (trichloroacetic acid) (pPreprecipitation of albumin along with bilirubin by trichloroacetic acid beforehand is suggested as an approach to correct the bilirubin interference. Conclusion: From this study it is concluded that bilirubin have negative interference on serum creatinine level. And this is corrected by using deproteinizer trichloroacetic acid. Keywords: Serum Creatinine, Serum bilirubin, Negative .intereference

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Introduction: Serum creatinine is a useful diagnostic parameter of kidney function. Its concentration reflects glomerular filtration rate. Because of negative interference of bilirubin over creatinine level, may mislead the clinician. The most common and serious problems in the determination of serum creatinine concentration by the kinetic Jaffe method is the negative interference by bilirubin. Materials and Methods: This cross sectional study was done on 160 patients which have high bilirubin level, taken from B. J. Medical College, Civil hospital, Ahmedabad from August 2013 to December 2013. These samples were studied for interference of total bilirubin on measurement of Serum creatinine level before and after treating with deproteinizer (trichloroacetic acid 0.55 mmol/ltr). Serum bilirubin and serum creatinine level were measured by modified Jendrassik & Groff’s method and kinetic Jaffe’s reaction respectively by using Erba XL-640 fully auto analyzer. Results: In this study significant difference was found in Serum Creatinine level with the samples of high bilirubin content before and after treating with deproteinizer (trichloroacetic acid) (pPreprecipitation of albumin along with bilirubin by trichloroacetic acid beforehand is suggested as an approach to correct the bilirubin interference. Conclusion: From this study it is concluded that bilirubin have negative interference on serum creatinine level. And this is corrected by using deproteinizer trichloroacetic acid. Keywords: Serum Creatinine, Serum bilirubin, Negative .intereference

Key concepts: Bilirubin, Creatinine, Trichloroacetic acid, Renal function, Albumin, Chromatography, Serum bilirubin, Internal medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Use of deproteinizer to eliminate interference of high bilirubin on measurement of serum creatinine by the kinetic jaffe reaction — Research Paper | ScholarLens