2017Annals of Clinical Biochemistry International Journal of Laboratory MedicineRequires access

Effects of bilirubin photoisomers on the measurement of direct bilirubin by the bilirubin oxidase method

Hitoshi Okada, Kou Kawada, Susumu Itoh, Miyo Ozaki, Isami Kakutani, Takeshi Arai, Kosuke Koyano, Saneyuki Yasuda, Takashi Iwase, Koji Murao, Takashi Kusaka

Open publisher page 13 citations

Abstract

Background We occasionally encounter increases in direct bilirubin value on reanalysis of the surplus serum collected in the past from a neonate with indirect hyperbilirubinemia. But the details of this phenomenon are unclear. We evaluated the change of direct bilirubin and the relation of bilirubin photoisomer of the serum exposed to room light. Methods Surplus serum samples from neonates with indirect hyperbilirubinemia were exposed to room light for 24 h. The bilirubin fraction assay of samples was performed by the bilirubin oxidase method (Nescauto and Aqua-auto Kainos reagent) and high-performance liquid chromatography. Results Direct bilirubin increased significantly from 0.61 to 2.36 mg/dL. The respective ratios of bilirubin photoisomers before and after exposure were as follows: cyclobilirubin (0.007 to 0.29) and (EZ)-bilirubin (0.018 to 0.041) increased significantly, (ZZ)-bilirubin decreased 0.84 to 0.55 significantly. The difference of the cyclobilirubin concentration was most closely associated with those of the direct bilirubin concentration. Conclusion Direct bilirubin value was increased after exposure to the room light, and increase in direct bilirubin was significantly correlated by cyclobilirubin increase in the serum samples from neonates with indirect hyperbilirubinemia.

About this research paper

What this paper is about

Background We occasionally encounter increases in direct bilirubin value on reanalysis of the surplus serum collected in the past from a neonate with indirect hyperbilirubinemia. But the details of this phenomenon are unclear. We evaluated the change of direct bilirubin and the relation of bilirubin photoisomer of the serum exposed to room light. Methods Surplus serum samples from neonates with indirect hyperbilirubinemia were exposed to room light for 24 h. The bilirubin fraction assay of samples was performed by the bilirubin oxidase method (Nescauto and Aqua-auto Kainos reagent) and high-performance liquid chromatography. Results Direct bilirubin increased significantly from 0.61 to 2.36 mg/dL. The respective ratios of bilirubin photoisomers before and after exposure were as follows: cyclobilirubin (0.007 to 0.29) and (EZ)-bilirubin (0.018 to 0.041) increased significantly, (ZZ)-bilirubin decreased 0.84 to 0.55 significantly. The difference of the cyclobilirubin concentration was most closely associated with those of the direct bilirubin concentration. Conclusion Direct bilirubin value was increased after exposure to the room light, and increase in direct bilirubin was significantly correlated by cyclobilirubin increase in the serum samples from neonates with indirect hyperbilirubinemia.

Why it matters

OpenAlex reports 13 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Background We occasionally encounter increases in direct bilirubin value on reanalysis of the surplus serum collected in the past from a neonate with indirect hyperbilirubinemia. But the details of this phenomenon are unclear. We evaluated the change of direct bilirubin and the relation of bilirubin photoisomer of the serum exposed to room light. Methods Surplus serum samples from neonates with indirect hyperbilirubinemia were exposed to room light for 24 h. The bilirubin fraction assay of samples was performed by the bilirubin oxidase method (Nescauto and Aqua-auto Kainos reagent) and high-performance liquid chromatography. Results Direct bilirubin increased significantly from 0.61 to 2.36 mg/dL. The respective ratios of bilirubin photoisomers before and after exposure were as follows: cyclobilirubin (0.007 to 0.29) and (EZ)-bilirubin (0.018 to 0.041) increased significantly, (ZZ)-bilirubin decreased 0.84 to 0.55 significantly. The difference of the cyclobilirubin concentration was most closely associated with those of the direct bilirubin concentration. Conclusion Direct bilirubin value was increased after exposure to the room light, and increase in direct bilirubin was significantly correlated by cyclobilirubin increase in the serum samples from neonates with indirect hyperbilirubinemia.

Key concepts: Bilirubin, Direct bilirubin, Bilirubin oxidase, Serum bilirubin, Chemistry, Internal medicine, Chromatography, Biochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Effects of bilirubin photoisomers on the measurement of direct bilirubin by the bilirubin oxidase method — Research Paper | ScholarLens