2007PubMedRequires access

Estimation of total and direct serum bilirubin using modified micro assay method.

Afsheen Aman, Shah Ali Ul Qader, Saeeda Bano

Open publisher page 4 citations

Abstract

Estimation of total and direct bilirubin in serum plays an important role in differential diagnosis of hyperbilirubinemia. Several direct spectrophotometric methods are commercially available for total and direct bilirubin estimation in which the amount of the sample (serum) varies from 200 ml to 800 ml. It is difficult to collect such amount of serum from infants, as neonatal jaundice is the most common problem in this age group. To overcome this problem modified micro assay method was developed using dimethylsulfoxide (DMSO). The amount of the serum sample is reduced from 100 ml to 20 ml per test for both total and direct bilirubin. A method comparison study was performed using 100 consecutive serum samples, by modified micro assay method and a reference Jendrassik-Grof method. Total bilirubin in these human serum samples ranged from 0.4-15.0 mg/dl and direct bilirubin ranged from 0.05-12.0 mg/dl. The results conclude that modified micro assay method had significant correlation with r-value of 0.99989 for total serum bilirubin and with r-value of 0.99971 for direct serum bilirubin. Linearity of the method is 20 mg/dl and 15 mg/dl for total and direct bilirubin, respectively. Monoreagent used during the assay is stable for 24 hours at 2-8 degrees C while the kit is stable for one year at 2-8 degrees C. In conclusion this micro assay method is rapid, reliable, simple and accurate for the estimation of total and direct bilirubin with small serum quantities. It is equally reliable for manual; semi automated and automated chemistry analyzers.

About this research paper

What this paper is about

Estimation of total and direct bilirubin in serum plays an important role in differential diagnosis of hyperbilirubinemia. Several direct spectrophotometric methods are commercially available for total and direct bilirubin estimation in which the amount of the sample (serum) varies from 200 ml to 800 ml. It is difficult to collect such amount of serum from infants, as neonatal jaundice is the most common problem in this age group. To overcome this problem modified micro assay method was developed using dimethylsulfoxide (DMSO). The amount of the serum sample is reduced from 100 ml to 20 ml per test for both total and direct bilirubin. A method comparison study was performed using 100 consecutive serum samples, by modified micro assay method and a reference Jendrassik-Grof method. Total bilirubin in these human serum samples ranged from 0.4-15.0 mg/dl and direct bilirubin ranged from 0.05-12.0 mg/dl. The results conclude that modified micro assay method had significant correlation with r-value of 0.99989 for total serum bilirubin and with r-value of 0.99971 for direct serum bilirubin. Linearity of the method is 20 mg/dl and 15 mg/dl for total and direct bilirubin, respectively. Monoreagent used during the assay is stable for 24 hours at 2-8 degrees C while the kit is stable for one year at 2-8 degrees C. In conclusion this micro assay method is rapid, reliable, simple and accurate for the estimation of total and direct bilirubin with small serum quantities. It is equally reliable for manual; semi automated and automated chemistry analyzers.

Why it matters

OpenAlex reports 4 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Estimation of total and direct bilirubin in serum plays an important role in differential diagnosis of hyperbilirubinemia. Several direct spectrophotometric methods are commercially available for total and direct bilirubin estimation in which the amount of the sample (serum) varies from 200 ml to 800 ml. It is difficult to collect such amount of serum from infants, as neonatal jaundice is the most common problem in this age group. To overcome this problem modified micro assay method was developed using dimethylsulfoxide (DMSO). The amount of the serum sample is reduced from 100 ml to 20 ml per test for both total and direct bilirubin. A method comparison study was performed using 100 consecutive serum samples, by modified micro assay method and a reference Jendrassik-Grof method. Total bilirubin in these human serum samples ranged from 0.4-15.0 mg/dl and direct bilirubin ranged from 0.05-12.0 mg/dl. The results conclude that modified micro assay method had significant correlation with r-value of 0.99989 for total serum bilirubin and with r-value of 0.99971 for direct serum bilirubin. Linearity of the method is 20 mg/dl and 15 mg/dl for total and direct bilirubin, respectively. Monoreagent used during the assay is stable for 24 hours at 2-8 degrees C while the kit is stable for one year at 2-8 degrees C. In conclusion this micro assay method is rapid, reliable, simple and accurate for the estimation of total and direct bilirubin with small serum quantities. It is equally reliable for manual; semi automated and automated chemistry analyzers.

Key concepts: Bilirubin, Direct bilirubin, Chemistry, Serum bilirubin, Chromatography, Jaundice, Gastroenterology, Biochemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Estimation of total and direct serum bilirubin using modified micro assay method. — Research Paper | ScholarLens