The discussion of serum D-dimer reference value examined by turbidimetric immunoassay
Xin-fen Tang, Zhonghua Zhao, Tong-shun Lin
Abstract
Xin-fen Tang, Zhonghua Zhao, Tong-shun Lin
Abstract
Objective To make the preliminary discussion of the serum D-dimer level in Normal popu-lation. Methods Serum D-dimer was detected by turbidimetric immunoassay on the Hitachi 7020 automatic bi-ochemistry analyzer. Results 338 apparently healthy controls were examined. The average value was 1.37 mg/ L,95% reference range 0. 1 ~ 2. 64 mg/L, assumes the normal distribution, male 165 examples, average value 1.28 mg/L,95% reference range 0. 15 ~2.41 mg/L; Female 173 examples,average value 1.46 mg/L,95% ref-erence scope 0. 04 ~ 2. 88 mg/L; In the healths controls, there was significantly deference of serum -dimer lev-el between the male and the female(P 0. 05) ; Compares with serum and heparin plasma, or the serum tube made by different country(Japan and China) , the difference has the extremely remarkable sta-tistics significance(P < 0. 001). Conclusion Preliminary defined the 95% reference value of serum D-dimer concentration was 0.1 ~2.64 mg/L; The serum and the heparin plasma D-dimer reference scope cannot use in common, but the relevance is good. Key words: Serum D-dimer; Normal population; Turbidimetric immunoassay
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To make the preliminary discussion of the serum D-dimer level in Normal popu-lation. Methods Serum D-dimer was detected by turbidimetric immunoassay on the Hitachi 7020 automatic bi-ochemistry analyzer. Results 338 apparently healthy controls were examined. The average value was 1.37 mg/ L,95% reference range 0. 1 ~ 2. 64 mg/L, assumes the normal distribution, male 165 examples, average value 1.28 mg/L,95% reference range 0. 15 ~2.41 mg/L; Female 173 examples,average value 1.46 mg/L,95% ref-erence scope 0. 04 ~ 2. 88 mg/L; In the healths controls, there was significantly deference of serum -dimer lev-el between the male and the female(P 0. 05) ; Compares with serum and heparin plasma, or the serum tube made by different country(Japan and China) , the difference has the extremely remarkable sta-tistics significance(P < 0. 001). Conclusion Preliminary defined the 95% reference value of serum D-dimer concentration was 0.1 ~2.64 mg/L; The serum and the heparin plasma D-dimer reference scope cannot use in common, but the relevance is good. Key words: Serum D-dimer; Normal population; Turbidimetric immunoassay
Key concepts: D-dimer, Immunoassay, Reference range, Dimer, Chemistry, Reference values, Population, Internal medicine