Validation of the Assay for D-dimer in Plasma by D-Dimer PLUS
Ling Qiu
Abstract
Ling Qiu
Abstract
Objective Validate the plasma d-dimer assay by D-Dimer PLUS.Methods According to the related documents of NCCLS,evaluate the performance of the plasma d-dimer assay by D-Dimer PLUS on the automated coagulation analyzer Sysmex CA7000.Results The low limit of the test was 83.86 μg/L;the linearity interval,0~2 000 μg/L;the recovery,93%~113%.The within-run precisions(coefficient of variability CV%) were 5.31%(low value) and 2.67%(high value);the total precisions 4.69%(low value) and 4.14%(high value).The test results of the D-Dimer PLUS were compared with those of mini-VIDAS(enzyme-linked immunosorbent assay ELISA).The coefficient of correlation was 0.915;the percentage of average bias was 634.6%.Endogenous interfering substances were also estimated in this experiment.The concentrations of conjugated bilirubin,chylomicra and hemoglobin which influenced the d-dimer test were 299 mg/L,882 FTU and 7.8 g/L.The test results didn't greatly alter when the plasma concentrations of direct bilirubin and rheumatoid factor reaching to 362 mg/L and 540,000 U/L.The validation reference value was 0~398 μg/L,higher than 0~324 μg/L offered by the manufacturer.So the reference interval needs to be reestablished.Conclusion The plasma d-dimer assay by D-Dimer PLUS had proper precision,accuracy and sensitivity for clinical requirement.It was applicable for the clinical diagnosis test.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective Validate the plasma d-dimer assay by D-Dimer PLUS.Methods According to the related documents of NCCLS,evaluate the performance of the plasma d-dimer assay by D-Dimer PLUS on the automated coagulation analyzer Sysmex CA7000.Results The low limit of the test was 83.86 μg/L;the linearity interval,0~2 000 μg/L;the recovery,93%~113%.The within-run precisions(coefficient of variability CV%) were 5.31%(low value) and 2.67%(high value);the total precisions 4.69%(low value) and 4.14%(high value).The test results of the D-Dimer PLUS were compared with those of mini-VIDAS(enzyme-linked immunosorbent assay ELISA).The coefficient of correlation was 0.915;the percentage of average bias was 634.6%.Endogenous interfering substances were also estimated in this experiment.The concentrations of conjugated bilirubin,chylomicra and hemoglobin which influenced the d-dimer test were 299 mg/L,882 FTU and 7.8 g/L.The test results didn't greatly alter when the plasma concentrations of direct bilirubin and rheumatoid factor reaching to 362 mg/L and 540,000 U/L.The validation reference value was 0~398 μg/L,higher than 0~324 μg/L offered by the manufacturer.So the reference interval needs to be reestablished.Conclusion The plasma d-dimer assay by D-Dimer PLUS had proper precision,accuracy and sensitivity for clinical requirement.It was applicable for the clinical diagnosis test.
Key concepts: D-dimer, Dimer, Coefficient of variation, Bilirubin, Chemistry, Detection limit, Chromatography, Analytical Chemistry (journal)