2014Traditional Chinese MedicineRequires access

Determination of hyperoside in Bushen-Yijing wan by Ion-Pair HPLC

王正军, 吕明

Open publisher page 0 citations

Abstract

Objective To establish a HPLC method for the determination of Hyperoside in Bushen-Yijing wan. Methods The HPLC system consisted of the Agilent HC-C18(4.6 mm×250 mm, 5μm)column was adopted. The mobile phase was consisted of acetonitrile(10)-HK2PO4(90)(0.85 g/L sodium heptanesulfonate,H3PO4 adjusted pH to 4.8), the flow rate was 1.0 ml/min, the column temperature was 30 ℃, and the UV detector was set at 360 nm. Results The linear response range was 3.0~60.0μg/ml(r=0.999 9). The average recovery of hyperoside was 98.2%, and RSD1.53%. Conclusions The method is simple, rapid, accurate and repeatable. It can be applied in determination of Hyperoside in Bushen-Yijing wan. Key words: Hyperoside; Bushen-Yijing wan; Ion-Pair HPLC

About this research paper

What this paper is about

Objective To establish a HPLC method for the determination of Hyperoside in Bushen-Yijing wan. Methods The HPLC system consisted of the Agilent HC-C18(4.6 mm×250 mm, 5μm)column was adopted. The mobile phase was consisted of acetonitrile(10)-HK2PO4(90)(0.85 g/L sodium heptanesulfonate,H3PO4 adjusted pH to 4.8), the flow rate was 1.0 ml/min, the column temperature was 30 ℃, and the UV detector was set at 360 nm. Results The linear response range was 3.0~60.0μg/ml(r=0.999 9). The average recovery of hyperoside was 98.2%, and RSD1.53%. Conclusions The method is simple, rapid, accurate and repeatable. It can be applied in determination of Hyperoside in Bushen-Yijing wan. Key words: Hyperoside; Bushen-Yijing wan; Ion-Pair HPLC

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a HPLC method for the determination of Hyperoside in Bushen-Yijing wan. Methods The HPLC system consisted of the Agilent HC-C18(4.6 mm×250 mm, 5μm)column was adopted. The mobile phase was consisted of acetonitrile(10)-HK2PO4(90)(0.85 g/L sodium heptanesulfonate,H3PO4 adjusted pH to 4.8), the flow rate was 1.0 ml/min, the column temperature was 30 ℃, and the UV detector was set at 360 nm. Results The linear response range was 3.0~60.0μg/ml(r=0.999 9). The average recovery of hyperoside was 98.2%, and RSD1.53%. Conclusions The method is simple, rapid, accurate and repeatable. It can be applied in determination of Hyperoside in Bushen-Yijing wan. Key words: Hyperoside; Bushen-Yijing wan; Ion-Pair HPLC

Key concepts: Hyperoside, Chromatography, Chemistry, High-performance liquid chromatography, Acetonitrile, Sodium, Biochemistry, Quercetin

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of hyperoside in Bushen-Yijing wan by Ion-Pair HPLC — Research Paper | ScholarLens