2014Guiding Journal of Traditional Chinese Medicine and PharmacyRequires access

Determination of Hyperoside in Jiawei Shuilu Wan by HPLC

Yang Hai-l

Open publisher page 0 citations

Abstract

Objective:To establish a HPLC method for the determination of Hyperoside in Jiawei Shuilu wan.Methods:The HPLC system consisted of the DIONEX-C18(4.6 mm×250 mm,5 μm)column,the mobile phase consisted of acetonitrile(10)-0.1% H3PO4(90);the flow rate was 1.0 mL·min-1;the column temperature was 30 ℃;The UV detector was set at 360 nm.Results:The linear response range was 4.0-80.0 μg/mL(r=0.9998).The average recovery of hyperoside was 97.6%,and RSD% =1.26%.Conclusions:The method is simple,rapid,accurate and repeatable.It can be applied in determination of Hyperoside in Jiawei Shuilu wan.

About this research paper

What this paper is about

Objective:To establish a HPLC method for the determination of Hyperoside in Jiawei Shuilu wan.Methods:The HPLC system consisted of the DIONEX-C18(4.6 mm×250 mm,5 μm)column,the mobile phase consisted of acetonitrile(10)-0.1% H3PO4(90);the flow rate was 1.0 mL·min-1;the column temperature was 30 ℃;The UV detector was set at 360 nm.Results:The linear response range was 4.0-80.0 μg/mL(r=0.9998).The average recovery of hyperoside was 97.6%,and RSD% =1.26%.Conclusions:The method is simple,rapid,accurate and repeatable.It can be applied in determination of Hyperoside in Jiawei Shuilu wan.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish a HPLC method for the determination of Hyperoside in Jiawei Shuilu wan.Methods:The HPLC system consisted of the DIONEX-C18(4.6 mm×250 mm,5 μm)column,the mobile phase consisted of acetonitrile(10)-0.1% H3PO4(90);the flow rate was 1.0 mL·min-1;the column temperature was 30 ℃;The UV detector was set at 360 nm.Results:The linear response range was 4.0-80.0 μg/mL(r=0.9998).The average recovery of hyperoside was 97.6%,and RSD% =1.26%.Conclusions:The method is simple,rapid,accurate and repeatable.It can be applied in determination of Hyperoside in Jiawei Shuilu wan.

Key concepts: Hyperoside, Chromatography, High-performance liquid chromatography, Chemistry, Acetonitrile, Linear range, Detection limit, Quercetin

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Hyperoside in Jiawei Shuilu Wan by HPLC — Research Paper | ScholarLens