2015Journal of Hubei University of Chinese MedicineRequires access

Determination of Hyperoside in Fu'an Granule by HPLC

LI Zhi-ha

Open publisher page 0 citations

Abstract

Objective To establish a HPLC method for the determination of hyperoside in Fu'an granule. Method The HPLC system consisted of the Fortis C18( 4. 6mm × 250 mm,5μm) column,the mobile phase consisted of acetonitrile- 0. 1% H3PO4( 14: 86),the flow rate was 1. 0m L / min,the column temperature was 30℃,the UV detector was set at 360 nm. Results The linear response range was 1. 8- 36. 0μg /m L( r = 0. 9999). The average recovery of hyperoside was 99. 2%,and RSD was 1. 18%. Conclusions The method is simple,rapid,accurate and repeatable. It can be applied in determination of hyperoside in Fu'an granule.

About this research paper

What this paper is about

Objective To establish a HPLC method for the determination of hyperoside in Fu'an granule. Method The HPLC system consisted of the Fortis C18( 4. 6mm × 250 mm,5μm) column,the mobile phase consisted of acetonitrile- 0. 1% H3PO4( 14: 86),the flow rate was 1. 0m L / min,the column temperature was 30℃,the UV detector was set at 360 nm. Results The linear response range was 1. 8- 36. 0μg /m L( r = 0. 9999). The average recovery of hyperoside was 99. 2%,and RSD was 1. 18%. Conclusions The method is simple,rapid,accurate and repeatable. It can be applied in determination of hyperoside in Fu'an granule.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a HPLC method for the determination of hyperoside in Fu'an granule. Method The HPLC system consisted of the Fortis C18( 4. 6mm × 250 mm,5μm) column,the mobile phase consisted of acetonitrile- 0. 1% H3PO4( 14: 86),the flow rate was 1. 0m L / min,the column temperature was 30℃,the UV detector was set at 360 nm. Results The linear response range was 1. 8- 36. 0μg /m L( r = 0. 9999). The average recovery of hyperoside was 99. 2%,and RSD was 1. 18%. Conclusions The method is simple,rapid,accurate and repeatable. It can be applied in determination of hyperoside in Fu'an granule.

Key concepts: Hyperoside, Chromatography, Granule (geology), High-performance liquid chromatography, Chemistry, Acetonitrile, Linear range, Materials science

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Hyperoside in Fu'an Granule by HPLC — Research Paper | ScholarLens