2011Traditional Chinese MedicineRequires access

Simultaneous determination of evodiamine and rutaecarpine of compound Wuzhuyu ointment by HPLC

Zhou Xue-hong, Zhihao Li

Open publisher page 0 citations

Abstract

Objective To establish a method for the determination of evodiamine and rutaecarpine of compound wuzhuyu ointment.Methods HPLC method was used with Agilent HC-C18(250 mm× 4.6 mm,5 μm) column and the mobile phase being acetonitrile-0.08% ocane sutfonic acid sodium(41:59).The flow rate was 0.8 ml/min,the column temperature was 30℃,and the UV detector was set at 225 nm.Results The linear ranges of evodiamine and rutaecarpine were 0.62~ 12.40 μg/ml (r=0.9997) and 0.24~4.8 0 μg/ml (r=0.9996),respectively.The average recovery of evodiamine and rutaecarpine was 97.9% and 98.0%,respectively.Conclusion The method is simple,repeatable and accurate.It can be applied in quantitative determination of evodiamine and rutaecarpine in compound Wuzhuyu ointment. Key words: Evodiamine;  Rutaecarpine;  Compound Wuzhuyuointment;  HPLC

About this research paper

What this paper is about

Objective To establish a method for the determination of evodiamine and rutaecarpine of compound wuzhuyu ointment.Methods HPLC method was used with Agilent HC-C18(250 mm× 4.6 mm,5 μm) column and the mobile phase being acetonitrile-0.08% ocane sutfonic acid sodium(41:59).The flow rate was 0.8 ml/min,the column temperature was 30℃,and the UV detector was set at 225 nm.Results The linear ranges of evodiamine and rutaecarpine were 0.62~ 12.40 μg/ml (r=0.9997) and 0.24~4.8 0 μg/ml (r=0.9996),respectively.The average recovery of evodiamine and rutaecarpine was 97.9% and 98.0%,respectively.Conclusion The method is simple,repeatable and accurate.It can be applied in quantitative determination of evodiamine and rutaecarpine in compound Wuzhuyu ointment. Key words: Evodiamine;  Rutaecarpine;  Compound Wuzhuyuointment;  HPLC

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a method for the determination of evodiamine and rutaecarpine of compound wuzhuyu ointment.Methods HPLC method was used with Agilent HC-C18(250 mm× 4.6 mm,5 μm) column and the mobile phase being acetonitrile-0.08% ocane sutfonic acid sodium(41:59).The flow rate was 0.8 ml/min,the column temperature was 30℃,and the UV detector was set at 225 nm.Results The linear ranges of evodiamine and rutaecarpine were 0.62~ 12.40 μg/ml (r=0.9997) and 0.24~4.8 0 μg/ml (r=0.9996),respectively.The average recovery of evodiamine and rutaecarpine was 97.9% and 98.0%,respectively.Conclusion The method is simple,repeatable and accurate.It can be applied in quantitative determination of evodiamine and rutaecarpine in compound Wuzhuyu ointment. Key words: Evodiamine;  Rutaecarpine;  Compound Wuzhuyuointment;  HPLC

Key concepts: Rutaecarpine, Evodiamine, Chromatography, High-performance liquid chromatography, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous determination of evodiamine and rutaecarpine of compound Wuzhuyu ointment by HPLC — Research Paper | ScholarLens