2006•PubMedRequires access

[Determination of diltiazem hydrochloride injection by high-performance liquid chromatography].

Tang Ling, Ting Zhang, Xinzhong Li

Open publisher page 0 citations

Abstract

OBJECTIVE: To establish an high-performance liquid chromatography (HPLC) method for the determination of diltiazem hydrochloride injection. METHODS: The assay was conducted on a NUCLEODUR C18 column with buffer solution (pH6.2)-acetonitrile-methanol (40:30:30) as the mobile phase and the detection wavelength was 240 nm. RESULTS: Diltiazem hydrochloride and relevant substances could be separated under the condition. The linear concentration range of diltiazem hydrochloride was 4 - 200mg/L with the recovery of 100.22% (RSD = 0.37%). CONCLUSION: The method may be used for the determination of diltiazem hydrochloride injection.

About this research paper

What this paper is about

OBJECTIVE: To establish an high-performance liquid chromatography (HPLC) method for the determination of diltiazem hydrochloride injection. METHODS: The assay was conducted on a NUCLEODUR C18 column with buffer solution (pH6.2)-acetonitrile-methanol (40:30:30) as the mobile phase and the detection wavelength was 240 nm. RESULTS: Diltiazem hydrochloride and relevant substances could be separated under the condition. The linear concentration range of diltiazem hydrochloride was 4 - 200mg/L with the recovery of 100.22% (RSD = 0.37%). CONCLUSION: The method may be used for the determination of diltiazem hydrochloride injection.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To establish an high-performance liquid chromatography (HPLC) method for the determination of diltiazem hydrochloride injection. METHODS: The assay was conducted on a NUCLEODUR C18 column with buffer solution (pH6.2)-acetonitrile-methanol (40:30:30) as the mobile phase and the detection wavelength was 240 nm. RESULTS: Diltiazem hydrochloride and relevant substances could be separated under the condition. The linear concentration range of diltiazem hydrochloride was 4 - 200mg/L with the recovery of 100.22% (RSD = 0.37%). CONCLUSION: The method may be used for the determination of diltiazem hydrochloride injection.

Key concepts: Diltiazem hydrochloride, Diltiazem, Chromatography, High-performance liquid chromatography, Chemistry, Hydrochloride, Acetonitrile, Linear range

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of diltiazem hydrochloride injection by high-performance liquid chromatography]. — Research Paper | ScholarLens