Stability-Indicating High Performance liquid Chromatographic Determination of Diltiazem Hydrochloride
Mohamed E. Abdel-Hamid, M.Saadeh Suleiman, Naji M. Najib, H. Muti
Abstract
Mohamed E. Abdel-Hamid, M.Saadeh Suleiman, Naji M. Najib, H. Muti
Abstract
A rapid, selective and accurate high-performance liquid chromatography method (HPLC) for the determination of diltiazem hydrochloride using clonazepam as internal standard is developed. The investigated compounds were eluted from 5 u Micropak MCH-5 reversed phase column at ambient temperature with a mobile phase comprising of acetonitrile-water (48:52%) at pH 3.3 and containing 0. 01M sodium-n-octane sulfonate as an ion pairing substance. The mobile phase was pumped at a flow rate of 1 ml min−1 and the effluent was monitored at 239 nm. The retention times of the internal standard and diltiazem were at 3 min and 9 min, respectively. A linear relationship was derived between the peak height ratio (diltiazem/clonazepam) and diltiazem concentration over the range 1–10 μg ml−1. Detection limit for the drug is 0.2 μg ml−1 at 0.01 aufs. The developed procedure was applied to study the stability of diltiazem in the presence of its degradation products as well as in the presence of formulation excipients.
OpenAlex reports 9 citations for this work. Citation counts describe recorded attention and do not establish research quality.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A rapid, selective and accurate high-performance liquid chromatography method (HPLC) for the determination of diltiazem hydrochloride using clonazepam as internal standard is developed. The investigated compounds were eluted from 5 u Micropak MCH-5 reversed phase column at ambient temperature with a mobile phase comprising of acetonitrile-water (48:52%) at pH 3.3 and containing 0. 01M sodium-n-octane sulfonate as an ion pairing substance. The mobile phase was pumped at a flow rate of 1 ml min−1 and the effluent was monitored at 239 nm. The retention times of the internal standard and diltiazem were at 3 min and 9 min, respectively. A linear relationship was derived between the peak height ratio (diltiazem/clonazepam) and diltiazem concentration over the range 1–10 μg ml−1. Detection limit for the drug is 0.2 μg ml−1 at 0.01 aufs. The developed procedure was applied to study the stability of diltiazem in the presence of its degradation products as well as in the presence of formulation excipients.
Key concepts: Chemistry, Chromatography, Diltiazem, Diltiazem hydrochloride, High-performance liquid chromatography, Detection limit, Calcium, Organic chemistry