2005•Zhongguo xiandai yixue/Zhongguo xiandai yixue zazhiRequires access

Ditermination of diltiazem hydrochloride for injection by internal Standard

Wei Liu

Open publisher page 0 citations

Abstract

[Objective] To establish an HPLC method of determination of diltiazem hydrochloride.[Methods] Chromatographic conditions included Diamonsil ODS C18 column was used with 50℃ column temperature and a mobile phase of α-caphor-sulfonic acid-sodium acetate buffer-solution-acetonitrile-methanol(25∶40∶35)at a flow rate of 1.2 mL/min and 240 nm detection,and phenyl benzoate was used as internal standard.[Results] The linear of diltiazem hydrochloride was 0.1007~0.5035 mg/mL,the recovery was 97.85%,RSD=0.799%(n=9).[Conclusions] This methods is simple,rapid,accurate and reliable.

About this research paper

What this paper is about

[Objective] To establish an HPLC method of determination of diltiazem hydrochloride.[Methods] Chromatographic conditions included Diamonsil ODS C18 column was used with 50℃ column temperature and a mobile phase of α-caphor-sulfonic acid-sodium acetate buffer-solution-acetonitrile-methanol(25∶40∶35)at a flow rate of 1.2 mL/min and 240 nm detection,and phenyl benzoate was used as internal standard.[Results] The linear of diltiazem hydrochloride was 0.1007~0.5035 mg/mL,the recovery was 97.85%,RSD=0.799%(n=9).[Conclusions] This methods is simple,rapid,accurate and reliable.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

[Objective] To establish an HPLC method of determination of diltiazem hydrochloride.[Methods] Chromatographic conditions included Diamonsil ODS C18 column was used with 50℃ column temperature and a mobile phase of α-caphor-sulfonic acid-sodium acetate buffer-solution-acetonitrile-methanol(25∶40∶35)at a flow rate of 1.2 mL/min and 240 nm detection,and phenyl benzoate was used as internal standard.[Results] The linear of diltiazem hydrochloride was 0.1007~0.5035 mg/mL,the recovery was 97.85%,RSD=0.799%(n=9).[Conclusions] This methods is simple,rapid,accurate and reliable.

Key concepts: Diltiazem hydrochloride, Chromatography, Chemistry, High-performance liquid chromatography, Diltiazem, Acetonitrile, Methanol, Sulfonic acid

Related papers

Back to paper searchBrowse research topicsOriginal source
Ditermination of diltiazem hydrochloride for injection by internal Standard — Research Paper | ScholarLens