2005PubMedRequires access

[Determination of oxymatrine content and its related substances in oxymatrine capsule by HPLC].

Wen‐Wei Qiu, Shujuan Jian, Huikang Gong

Open publisher page 0 citations

Abstract

OBJECTIVE: To determine oxymatrine content and its related substances in oxymatrine capsule. METHODS: A HPLC method was adopted. C18 column was used. The mobile phase consisted of phosphate buffer solution-methanol (85:15). The UV detective wavelength was 210 nm. RESULTS: The calibration curve of oxymatrine was linear in the range of 6.952 - 20.856 microg/ml (r = 0.9999). The calibration curve of N-oxysophocarpine was linear in the range of 0.1837 - 0.5510 microg/ml (r = 0.9997). CONCLUSIONS: The method is simple, rapid and accurate.

About this research paper

What this paper is about

OBJECTIVE: To determine oxymatrine content and its related substances in oxymatrine capsule. METHODS: A HPLC method was adopted. C18 column was used. The mobile phase consisted of phosphate buffer solution-methanol (85:15). The UV detective wavelength was 210 nm. RESULTS: The calibration curve of oxymatrine was linear in the range of 6.952 - 20.856 microg/ml (r = 0.9999). The calibration curve of N-oxysophocarpine was linear in the range of 0.1837 - 0.5510 microg/ml (r = 0.9997). CONCLUSIONS: The method is simple, rapid and accurate.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To determine oxymatrine content and its related substances in oxymatrine capsule. METHODS: A HPLC method was adopted. C18 column was used. The mobile phase consisted of phosphate buffer solution-methanol (85:15). The UV detective wavelength was 210 nm. RESULTS: The calibration curve of oxymatrine was linear in the range of 6.952 - 20.856 microg/ml (r = 0.9999). The calibration curve of N-oxysophocarpine was linear in the range of 0.1837 - 0.5510 microg/ml (r = 0.9997). CONCLUSIONS: The method is simple, rapid and accurate.

Key concepts: Oxymatrine, Calibration curve, Chromatography, Capsule, High-performance liquid chromatography, Phosphate buffered saline, Linear range, Chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
[Determination of oxymatrine content and its related substances in oxymatrine capsule by HPLC]. — Research Paper | ScholarLens