2005Traditional Chinese Drug Research and Clinical PharmacologyRequires access

Determination of Oxymatrine in Oxymatrine Injection by HPLC

Yongjun Wang

Open publisher page 0 citations

Abstract

Objective To develop a HPLC method for the determination of oxymatrine in Oxymatrin Injection.Methods A RP-HPLC method with Lichrospher 5 ODS C18 column(4.6 mm× 250 mm,5 μ m) was used,and the mobile phase was the mixture of acetonnitrile-pH2.0 sulphate buffer solution(7∶93) at the f low rate of 1.0mL/min.The column temperature was 30 ℃,the UV detection wave length was 220 nm and the injection volume was 20 μ L.Results The calibra tion curve was linear(r=1.0000) in the range of 3.63~ 116.04 μ g/mL for oxyma trine.The mean recovery was 100.1 %(RSD=0.86 %,n=6).Conclusion Thi s method is effective and can be used for the determination of oxymatrine in Oxymatrine Injection.

About this research paper

What this paper is about

Objective To develop a HPLC method for the determination of oxymatrine in Oxymatrin Injection.Methods A RP-HPLC method with Lichrospher 5 ODS C18 column(4.6 mm× 250 mm,5 μ m) was used,and the mobile phase was the mixture of acetonnitrile-pH2.0 sulphate buffer solution(7∶93) at the f low rate of 1.0mL/min.The column temperature was 30 ℃,the UV detection wave length was 220 nm and the injection volume was 20 μ L.Results The calibra tion curve was linear(r=1.0000) in the range of 3.63~ 116.04 μ g/mL for oxyma trine.The mean recovery was 100.1 %(RSD=0.86 %,n=6).Conclusion Thi s method is effective and can be used for the determination of oxymatrine in Oxymatrine Injection.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To develop a HPLC method for the determination of oxymatrine in Oxymatrin Injection.Methods A RP-HPLC method with Lichrospher 5 ODS C18 column(4.6 mm× 250 mm,5 μ m) was used,and the mobile phase was the mixture of acetonnitrile-pH2.0 sulphate buffer solution(7∶93) at the f low rate of 1.0mL/min.The column temperature was 30 ℃,the UV detection wave length was 220 nm and the injection volume was 20 μ L.Results The calibra tion curve was linear(r=1.0000) in the range of 3.63~ 116.04 μ g/mL for oxyma trine.The mean recovery was 100.1 %(RSD=0.86 %,n=6).Conclusion Thi s method is effective and can be used for the determination of oxymatrine in Oxymatrine Injection.

Key concepts: Oxymatrine, Chromatography, High-performance liquid chromatography, Chemistry, Calibration curve, Recovery rate, Linear relationship, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Oxymatrine in Oxymatrine Injection by HPLC — Research Paper | ScholarLens