2007•Shenyang Yaoke Daxue xuebaoRequires access

Simultaneous determination of paeoniflorin and hesperidin in Yiwei oral solution by HPLC

Zhao Huai-qing

Open publisher page 0 citations

Abstract

Objective To develop a HPLC method for simultaneous determination of paeoniflorin and hesperidin in Yiwei(traditional Chinese medicines) oral solution.Methods The analysis was carried out with a Kromasil ODS-1(4.6 mm ×250 mm,5 μm) column and a mobile phase of acetonitrile-0.1%phosphoric acid solution(21:79).The flow rate was 1.0 mL·min-1 and column temperature was 35 ℃.The detection wavelength was set at 230 nm.Results The calibration curve was linear within the range of 7140 mg·L-1(r=0.999 6) and 6-120 mg·L-1(r=0.999 5) for paeonifloin and hesperidin respectively,the average recoveries were 98.5%(RSD=0.67%) and 98.7%(RSD=1.1%) for paeoniflorin and hesperidin respectively.Conclusions This method is convenient,accurate and reproducible for determination of paeoniflorin and hesperidin in Yiwei oral solution.

About this research paper

What this paper is about

Objective To develop a HPLC method for simultaneous determination of paeoniflorin and hesperidin in Yiwei(traditional Chinese medicines) oral solution.Methods The analysis was carried out with a Kromasil ODS-1(4.6 mm ×250 mm,5 μm) column and a mobile phase of acetonitrile-0.1%phosphoric acid solution(21:79).The flow rate was 1.0 mL·min-1 and column temperature was 35 ℃.The detection wavelength was set at 230 nm.Results The calibration curve was linear within the range of 7140 mg·L-1(r=0.999 6) and 6-120 mg·L-1(r=0.999 5) for paeonifloin and hesperidin respectively,the average recoveries were 98.5%(RSD=0.67%) and 98.7%(RSD=1.1%) for paeoniflorin and hesperidin respectively.Conclusions This method is convenient,accurate and reproducible for determination of paeoniflorin and hesperidin in Yiwei oral solution.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To develop a HPLC method for simultaneous determination of paeoniflorin and hesperidin in Yiwei(traditional Chinese medicines) oral solution.Methods The analysis was carried out with a Kromasil ODS-1(4.6 mm ×250 mm,5 μm) column and a mobile phase of acetonitrile-0.1%phosphoric acid solution(21:79).The flow rate was 1.0 mL·min-1 and column temperature was 35 ℃.The detection wavelength was set at 230 nm.Results The calibration curve was linear within the range of 7140 mg·L-1(r=0.999 6) and 6-120 mg·L-1(r=0.999 5) for paeonifloin and hesperidin respectively,the average recoveries were 98.5%(RSD=0.67%) and 98.7%(RSD=1.1%) for paeoniflorin and hesperidin respectively.Conclusions This method is convenient,accurate and reproducible for determination of paeoniflorin and hesperidin in Yiwei oral solution.

Key concepts: Paeoniflorin, Hesperidin, Chromatography, Chemistry, Calibration curve, Phosphoric acid, High-performance liquid chromatography, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Simultaneous determination of paeoniflorin and hesperidin in Yiwei oral solution by HPLC — Research Paper | ScholarLens