2008•Central South PharmacyRequires access

Determination of icariin in kangguzengsheng pills by HPLC

Jiang Gui-ping

Open publisher page 0 citations

Abstract

Objective To develop an HPLC method for the determination of icariin in Kangguzengsheng pills.Methods A C18 column(4.6 mm×200 mm,5 μm),and a mobile phase composed of acetonitrile-water(26∶74)were adopted.The flow rate was 1.0 mL·min-1 and wave length was 270 nm.Results The linear range was 0.040 4~0.504 μg,r=0.999 98.The recovery of paeoniflorin was 98.4% with RSD=0.7%(n=6).Conclusion The determination method is simple and accurate,and can be used for the quality control of Kangguzengsheng pills.

About this research paper

What this paper is about

Objective To develop an HPLC method for the determination of icariin in Kangguzengsheng pills.Methods A C18 column(4.6 mm×200 mm,5 μm),and a mobile phase composed of acetonitrile-water(26∶74)were adopted.The flow rate was 1.0 mL·min-1 and wave length was 270 nm.Results The linear range was 0.040 4~0.504 μg,r=0.999 98.The recovery of paeoniflorin was 98.4% with RSD=0.7%(n=6).Conclusion The determination method is simple and accurate,and can be used for the quality control of Kangguzengsheng pills.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To develop an HPLC method for the determination of icariin in Kangguzengsheng pills.Methods A C18 column(4.6 mm×200 mm,5 μm),and a mobile phase composed of acetonitrile-water(26∶74)were adopted.The flow rate was 1.0 mL·min-1 and wave length was 270 nm.Results The linear range was 0.040 4~0.504 μg,r=0.999 98.The recovery of paeoniflorin was 98.4% with RSD=0.7%(n=6).Conclusion The determination method is simple and accurate,and can be used for the quality control of Kangguzengsheng pills.

Key concepts: Icariin, Paeoniflorin, Chromatography, High-performance liquid chromatography, Linear range, Chemistry, Content determination, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of icariin in kangguzengsheng pills by HPLC — Research Paper | ScholarLens