2005•Zhongguo shiyan fangjixue zazhiRequires access

Determination of the Contents of Icariin in Gushen Pills with HPLC

Zhibin An

Open publisher page 0 citations

Abstract

Objective:To establish the HPLC method for determination of icariin in Gushen pills.Method:HPLC was performed on a Diamonsil C_ 18 column (4.6×200mm,5μm) with acetonitrile-water(20∶80) as mobile phase.Detecting wavelength was 270nm and flow rate was 1.0mL/min.Result:A good linear relationship between peak area and concentration was noted at 0.15~2.10μg with a correlation coefficient of r=0.99998(n=6) for icariin.The recovery rate of icariin was 97.4%(RSD=2.17%).Conclusion:This method is accurate, repeatable and effective for quality control of Gushen pills.

About this research paper

What this paper is about

Objective:To establish the HPLC method for determination of icariin in Gushen pills.Method:HPLC was performed on a Diamonsil C_ 18 column (4.6×200mm,5μm) with acetonitrile-water(20∶80) as mobile phase.Detecting wavelength was 270nm and flow rate was 1.0mL/min.Result:A good linear relationship between peak area and concentration was noted at 0.15~2.10μg with a correlation coefficient of r=0.99998(n=6) for icariin.The recovery rate of icariin was 97.4%(RSD=2.17%).Conclusion:This method is accurate, repeatable and effective for quality control of Gushen pills.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish the HPLC method for determination of icariin in Gushen pills.Method:HPLC was performed on a Diamonsil C_ 18 column (4.6×200mm,5μm) with acetonitrile-water(20∶80) as mobile phase.Detecting wavelength was 270nm and flow rate was 1.0mL/min.Result:A good linear relationship between peak area and concentration was noted at 0.15~2.10μg with a correlation coefficient of r=0.99998(n=6) for icariin.The recovery rate of icariin was 97.4%(RSD=2.17%).Conclusion:This method is accurate, repeatable and effective for quality control of Gushen pills.

Key concepts: Icariin, Chromatography, High-performance liquid chromatography, Chemistry, Correlation coefficient, Linear correlation, Linear relationship, Pill

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of the Contents of Icariin in Gushen Pills with HPLC — Research Paper | ScholarLens