Method Evaluation on The Vanadate Oxidation for Determination of Total Bilirubin and Direct Bilirubin
Wu Min
Abstract
Wu Min
Abstract
Objective Method comparison of Wako vanadate oxidation with improved J-G method for determination of bilirubin.Methods We use the Wako vanadate oxidation reagent of bilirubin to determinate serum total bilirubin and direct bilirubin simultaneously,take a comparison with the method of improved J-G and also take run-in-run test,linear test,recovery test,interfere test of vanadate oxidation.Results Vanadate oxidation( Y )has good correlation with improved J-G (total bilirubin Y =0.992 6 X +2.234 4, r =0.999 1;direct bilirubin Y =0.996 8 X +1 169 4, r =0.998 2).Linear range of total bilirubin can attach to 684 μmol/L and direct bilirubin can attach to 342 μmol/L.The inter day CV for total bilirubin is 1.17% and direct bilirubin is 1.88%.The intra day CV for total bilirubin is 1.88% and direct bilirubin is 2.76%.Hemolyte,lipidemia and vitamin C have rarely interfere.The average recovery rate of total bilirubin is 98.7%,direct bilirubin is 102%.Conclusion Vanadate oxidate method is accurate and sensitive and it can be used in the routine determination of bilirubin.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective Method comparison of Wako vanadate oxidation with improved J-G method for determination of bilirubin.Methods We use the Wako vanadate oxidation reagent of bilirubin to determinate serum total bilirubin and direct bilirubin simultaneously,take a comparison with the method of improved J-G and also take run-in-run test,linear test,recovery test,interfere test of vanadate oxidation.Results Vanadate oxidation( Y )has good correlation with improved J-G (total bilirubin Y =0.992 6 X +2.234 4, r =0.999 1;direct bilirubin Y =0.996 8 X +1 169 4, r =0.998 2).Linear range of total bilirubin can attach to 684 μmol/L and direct bilirubin can attach to 342 μmol/L.The inter day CV for total bilirubin is 1.17% and direct bilirubin is 1.88%.The intra day CV for total bilirubin is 1.88% and direct bilirubin is 2.76%.Hemolyte,lipidemia and vitamin C have rarely interfere.The average recovery rate of total bilirubin is 98.7%,direct bilirubin is 102%.Conclusion Vanadate oxidate method is accurate and sensitive and it can be used in the routine determination of bilirubin.
Key concepts: Bilirubin, Vanadate, Direct bilirubin, Chemistry, Chromatography, Biochemistry, Gastroenterology, Medicine