Determination of Serum Total Bilirubin and Direct Bilirubin with Vandate Oxidation

Hao Ding

Open publisher page 0 citations

Abstract

Objective To compare Vanadate Oxidation and improve J G method in determination of bilirubin. Methods Vanadate Oxidation was used to determinied serum total bilirubin and direct bilirubin meanwhile, the method was compared with improved J G method. Results Vanadate oxidation was well correlated to improved K G method (Y 1=0.99X+1.39, r=0.98; Y 2=1.36 X+3.09, r=0.96) linear range of total bilirubin and direct bilirubin were 1.80 % and 2.13 %. The out date CV for total bilirubin and direct bilirubin were 99.6 % and 99.2 %. Hemoglobin, lipidemia and low concentration vitamin C less than 0.3 g/L did not significantly interfere with the detection. Conclusion Vanadata Oxidation is accurance and sensitivitv, and can be used in rountine determination of bilirubin

About this research paper

What this paper is about

Objective To compare Vanadate Oxidation and improve J G method in determination of bilirubin. Methods Vanadate Oxidation was used to determinied serum total bilirubin and direct bilirubin meanwhile, the method was compared with improved J G method. Results Vanadate oxidation was well correlated to improved K G method (Y 1=0.99X+1.39, r=0.98; Y 2=1.36 X+3.09, r=0.96) linear range of total bilirubin and direct bilirubin were 1.80 % and 2.13 %. The out date CV for total bilirubin and direct bilirubin were 99.6 % and 99.2 %. Hemoglobin, lipidemia and low concentration vitamin C less than 0.3 g/L did not significantly interfere with the detection. Conclusion Vanadata Oxidation is accurance and sensitivitv, and can be used in rountine determination of bilirubin

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To compare Vanadate Oxidation and improve J G method in determination of bilirubin. Methods Vanadate Oxidation was used to determinied serum total bilirubin and direct bilirubin meanwhile, the method was compared with improved J G method. Results Vanadate oxidation was well correlated to improved K G method (Y 1=0.99X+1.39, r=0.98; Y 2=1.36 X+3.09, r=0.96) linear range of total bilirubin and direct bilirubin were 1.80 % and 2.13 %. The out date CV for total bilirubin and direct bilirubin were 99.6 % and 99.2 %. Hemoglobin, lipidemia and low concentration vitamin C less than 0.3 g/L did not significantly interfere with the detection. Conclusion Vanadata Oxidation is accurance and sensitivitv, and can be used in rountine determination of bilirubin

Key concepts: Bilirubin, Medicine, Direct bilirubin, Serum bilirubin, Vanadate, Hemoglobin, Internal medicine, Gastroenterology