2011Guiyang yixueyuan xuebaoRequires access

An Evaluation on Type Sysmex XS-1000i Blood Corpuscle Analyzer′s Performance

Long Xuegui

Open publisher page 0 citations

Abstract

Objective:To evaluate the performance of Sysmex XS-1000i hematology analyzer(XS-1000i).Methods: According to the guidelines of International Committee for Standardization in Hematology(ICSH),the performance of XS-1000i was evaluated on items of precision,total repeatability,carrier contamination rates,linear range,comparability and WBC differential counts.Results: The precision,total repeatability,carrier contamination rates were all in the allowable range.The detection results showed a good linear relation in a broader concentration range and were well related with reference instrument.The precision of DC was acceptable,CV5.0%,and compared with manual method,the correlation coefficients were 0.367 to 0.821.Conclusion: The performance of XS-1000i is suitable for rapid screening of clinical blood analysis.

About this research paper

What this paper is about

Objective:To evaluate the performance of Sysmex XS-1000i hematology analyzer(XS-1000i).Methods: According to the guidelines of International Committee for Standardization in Hematology(ICSH),the performance of XS-1000i was evaluated on items of precision,total repeatability,carrier contamination rates,linear range,comparability and WBC differential counts.Results: The precision,total repeatability,carrier contamination rates were all in the allowable range.The detection results showed a good linear relation in a broader concentration range and were well related with reference instrument.The precision of DC was acceptable,CV5.0%,and compared with manual method,the correlation coefficients were 0.367 to 0.821.Conclusion: The performance of XS-1000i is suitable for rapid screening of clinical blood analysis.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To evaluate the performance of Sysmex XS-1000i hematology analyzer(XS-1000i).Methods: According to the guidelines of International Committee for Standardization in Hematology(ICSH),the performance of XS-1000i was evaluated on items of precision,total repeatability,carrier contamination rates,linear range,comparability and WBC differential counts.Results: The precision,total repeatability,carrier contamination rates were all in the allowable range.The detection results showed a good linear relation in a broader concentration range and were well related with reference instrument.The precision of DC was acceptable,CV5.0%,and compared with manual method,the correlation coefficients were 0.367 to 0.821.Conclusion: The performance of XS-1000i is suitable for rapid screening of clinical blood analysis.

Key concepts: Repeatability, Hematology analyzer, Comparability, Accuracy and precision, Nuclear medicine, Statistics, Medicine, Mathematics

Related papers

Back to paper searchBrowse research topicsOriginal source
An Evaluation on Type Sysmex XS-1000i Blood Corpuscle Analyzer′s Performance — Research Paper | ScholarLens