Comparison of Analysis Results Determined by Three Different Type Hematology Analyzers

Qian Jin

Open publisher page 0 citations

Abstract

Objective To compare the analysis results of three different type hematology analyzer to guarantee the consistency of laboratory data and promote the reliability of assay results. Methods The hematology analyzer Sysmex XS-1800 i was set as reference. The WBC,RBC,HB,HCT and PLT from fresh blood samples with high,medium and low value daily were analyzed by Sysmex XS-1800 i,Sysmex XN-2000 and Sysmex XS-800 i analyzer. The linearity and recursion of data on the basis of 1 /2 of external quality assessment permission error from American clinical laboratory amended draft( CLIA'88) were determined. Results The correlation index of assay data between different analyzer was more than 0. 975( P 0. 05). The analysis results of three different hematology analyzers were correlated very well between each other. Conclusion The assay data of three different hematology analyzers are comparability and could guarantee the consistency of blood samples examination and reliability of assay test.

About this research paper

What this paper is about

Objective To compare the analysis results of three different type hematology analyzer to guarantee the consistency of laboratory data and promote the reliability of assay results. Methods The hematology analyzer Sysmex XS-1800 i was set as reference. The WBC,RBC,HB,HCT and PLT from fresh blood samples with high,medium and low value daily were analyzed by Sysmex XS-1800 i,Sysmex XN-2000 and Sysmex XS-800 i analyzer. The linearity and recursion of data on the basis of 1 /2 of external quality assessment permission error from American clinical laboratory amended draft( CLIA'88) were determined. Results The correlation index of assay data between different analyzer was more than 0. 975( P 0. 05). The analysis results of three different hematology analyzers were correlated very well between each other. Conclusion The assay data of three different hematology analyzers are comparability and could guarantee the consistency of blood samples examination and reliability of assay test.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To compare the analysis results of three different type hematology analyzer to guarantee the consistency of laboratory data and promote the reliability of assay results. Methods The hematology analyzer Sysmex XS-1800 i was set as reference. The WBC,RBC,HB,HCT and PLT from fresh blood samples with high,medium and low value daily were analyzed by Sysmex XS-1800 i,Sysmex XN-2000 and Sysmex XS-800 i analyzer. The linearity and recursion of data on the basis of 1 /2 of external quality assessment permission error from American clinical laboratory amended draft( CLIA'88) were determined. Results The correlation index of assay data between different analyzer was more than 0. 975( P 0. 05). The analysis results of three different hematology analyzers were correlated very well between each other. Conclusion The assay data of three different hematology analyzers are comparability and could guarantee the consistency of blood samples examination and reliability of assay test.

Key concepts: Hematology analyzer, Medicine, Hematology, Internal medicine, Reliability (semiconductor), Consistency (knowledge bases), Mathematics, Quantum mechanics

Related papers

Back to paper searchBrowse research topicsOriginal source
Comparison of Analysis Results Determined by Three Different Type Hematology Analyzers — Research Paper | ScholarLens