Performances of MEK-7222K Hematology Analyzer

Xu Chenglai

Open publisher page 0 citations

Abstract

OBJECTIVE:To analyze the performances of MEK-7222K hematology analyzer(Japan).METHODS:The evaluation was performed on the indices of complete blood cells by using guidelines established in the International Committee for Standard-ization Haematology(ICSH)document.The performances of MEK-7222K hematology analyzer were evaluated from aspects of precision,total repeatability,carry-over rate,linearity,the correlation between the analyzer and microscope in leukocyte differential count,the its correlation to Sysmex XE-2100 in detection results,and the correlation between the mode of whole blood and capillary vessel blood of the instrument.RESULTS:The CV value of within-and between-batch precision and that of the total repeatability were all within the designed range.The carry-over rate was lower than 1%.The linearity was good.The correlation between the instrument and microscope in leukocyte differential count,between the instrument and Sysmex XE-2100 and between the mode of whole blood and capillary vessel blood of the instrument were all satisfactory.CONCLUSION:MEK-7222K automatic hematology analyzer was proved to be accurate and reliable in test results,and the perfomances of the analyzer could all meet the clinical needs,which serves as a choice for large,medium,and small size hospitals in China.

About this research paper

What this paper is about

OBJECTIVE:To analyze the performances of MEK-7222K hematology analyzer(Japan).METHODS:The evaluation was performed on the indices of complete blood cells by using guidelines established in the International Committee for Standard-ization Haematology(ICSH)document.The performances of MEK-7222K hematology analyzer were evaluated from aspects of precision,total repeatability,carry-over rate,linearity,the correlation between the analyzer and microscope in leukocyte differential count,the its correlation to Sysmex XE-2100 in detection results,and the correlation between the mode of whole blood and capillary vessel blood of the instrument.RESULTS:The CV value of within-and between-batch precision and that of the total repeatability were all within the designed range.The carry-over rate was lower than 1%.The linearity was good.The correlation between the instrument and microscope in leukocyte differential count,between the instrument and Sysmex XE-2100 and between the mode of whole blood and capillary vessel blood of the instrument were all satisfactory.CONCLUSION:MEK-7222K automatic hematology analyzer was proved to be accurate and reliable in test results,and the perfomances of the analyzer could all meet the clinical needs,which serves as a choice for large,medium,and small size hospitals in China.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE:To analyze the performances of MEK-7222K hematology analyzer(Japan).METHODS:The evaluation was performed on the indices of complete blood cells by using guidelines established in the International Committee for Standard-ization Haematology(ICSH)document.The performances of MEK-7222K hematology analyzer were evaluated from aspects of precision,total repeatability,carry-over rate,linearity,the correlation between the analyzer and microscope in leukocyte differential count,the its correlation to Sysmex XE-2100 in detection results,and the correlation between the mode of whole blood and capillary vessel blood of the instrument.RESULTS:The CV value of within-and between-batch precision and that of the total repeatability were all within the designed range.The carry-over rate was lower than 1%.The linearity was good.The correlation between the instrument and microscope in leukocyte differential count,between the instrument and Sysmex XE-2100 and between the mode of whole blood and capillary vessel blood of the instrument were all satisfactory.CONCLUSION:MEK-7222K automatic hematology analyzer was proved to be accurate and reliable in test results,and the perfomances of the analyzer could all meet the clinical needs,which serves as a choice for large,medium,and small size hospitals in China.

Key concepts: Hematology analyzer, Repeatability, Spectrum analyzer, Medicine, Hematology, Biomedical engineering, Internal medicine, Mathematics

Related papers

Back to paper searchBrowse research topicsOriginal source
Performances of MEK-7222K Hematology Analyzer — Research Paper | ScholarLens