The Evaluation of Performance of BC-5500 Plus and SYSMEX XS-800i Blood Cells Analyzer
Wei Chen
Abstract
Wei Chen
Abstract
Objective:To evaluate the main performance of BC-5500 plus and SYSMEX XS-800i automatic blood cells analyzer,to ensure the two instrument the veracity of test results and consistency.Methods:According to international hematology standardization commission(ICSH) with the related regulations,the performances of BC-5500 and SYSMEX XS-800i hematology analyzer were evaluated in regards regard to precision,carry-over rate,lineality,thecorrelation between the ABX-120 Heamatology analyzer in detectin results and the accuracy of WBC classification.Results:The CV value of with-and between-Batch precision and that of the total precision of BC-5500 and SYSMEX 800i were all within the designed range.The carry-over rate was lower than 1.0%.The correlation between ABX-120 was satisfactory.The accuracy of WBC classification meets the requirement.Conclusions:The performances of MINRAY BC-5500 and SYSMEX XS-800i hematology analyzer have proved to be accurate and reliable in test results.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective:To evaluate the main performance of BC-5500 plus and SYSMEX XS-800i automatic blood cells analyzer,to ensure the two instrument the veracity of test results and consistency.Methods:According to international hematology standardization commission(ICSH) with the related regulations,the performances of BC-5500 and SYSMEX XS-800i hematology analyzer were evaluated in regards regard to precision,carry-over rate,lineality,thecorrelation between the ABX-120 Heamatology analyzer in detectin results and the accuracy of WBC classification.Results:The CV value of with-and between-Batch precision and that of the total precision of BC-5500 and SYSMEX 800i were all within the designed range.The carry-over rate was lower than 1.0%.The correlation between ABX-120 was satisfactory.The accuracy of WBC classification meets the requirement.Conclusions:The performances of MINRAY BC-5500 and SYSMEX XS-800i hematology analyzer have proved to be accurate and reliable in test results.
Key concepts: ABX test, Hematology analyzer, Medicine, Spectrum analyzer, Standardization, Consistency (knowledge bases), Statistics, Internal medicine