2005Yaowu fenxi zazhiRequires access

RP-HPLC Determination of the Content of Flunarize Hydrochloride in Fiunarize Hydrochloride and Sodium Chloride Injection

Wen Jing-wei

Open publisher page 0 citations

Abstract

Objective:To establish RP-HPLC method for determination the content of flunarize hydrochloride in flunarize hydrochloride and sodium chloride injection.Method:C_(18) column(5μm,4.6 mm×250mm)was used at 30℃.The mobile phase consisted of methanol-0.01 tool·L~(-1) monopotassium phosphate(include 0.4% triethyl- amine,adjust to pH 3.5 with phosphoric acid)(75:25)and detected with UV 253 nm.The flow rate was 0.9mL· min~(-1).Results:The linear range of the method was 1-344μg·mL~(-1)(r=0.9999);The average recovery rate was 99.6% (n=9).Conclusion:The method is sample and accurate with good reproducibility and sensitivity.

About this research paper

What this paper is about

Objective:To establish RP-HPLC method for determination the content of flunarize hydrochloride in flunarize hydrochloride and sodium chloride injection.Method:C_(18) column(5μm,4.6 mm×250mm)was used at 30℃.The mobile phase consisted of methanol-0.01 tool·L~(-1) monopotassium phosphate(include 0.4% triethyl- amine,adjust to pH 3.5 with phosphoric acid)(75:25)and detected with UV 253 nm.The flow rate was 0.9mL· min~(-1).Results:The linear range of the method was 1-344μg·mL~(-1)(r=0.9999);The average recovery rate was 99.6% (n=9).Conclusion:The method is sample and accurate with good reproducibility and sensitivity.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To establish RP-HPLC method for determination the content of flunarize hydrochloride in flunarize hydrochloride and sodium chloride injection.Method:C_(18) column(5μm,4.6 mm×250mm)was used at 30℃.The mobile phase consisted of methanol-0.01 tool·L~(-1) monopotassium phosphate(include 0.4% triethyl- amine,adjust to pH 3.5 with phosphoric acid)(75:25)and detected with UV 253 nm.The flow rate was 0.9mL· min~(-1).Results:The linear range of the method was 1-344μg·mL~(-1)(r=0.9999);The average recovery rate was 99.6% (n=9).Conclusion:The method is sample and accurate with good reproducibility and sensitivity.

Key concepts: Chemistry, Chromatography, Phosphoric acid, High-performance liquid chromatography, Hydrochloride, Sodium, Methanol, Chloride