2010Qilu Pharmaceutical AffairsRequires access

Determination of ropisentron hydrochloride in Tropisentron Hydrochloride and Sodium Chloride Injection by HPLC

Chang Ming Li

Open publisher page 0 citations

Abstract

OBJECTIVE The content determination of ropisentron hydrochloride in tropisentron Hydrochloride and sodium chloride injection by RP-HPLC.METHODS Column was used with octadecyl silane boned silica gel as filler.The mobile phase was Methanol-water-acetonitrile-triethylamine(62∶26∶12∶0.2).The detection wavelength was 284nm.RESULTS Ropisentron hydrochloride showed a good linear relationship in the range of 2~40μg·mL-1(Y=15.623X+8.16,r=0.9997)and the average recovery was 99.72%,RSD was 0.63%.CONCLUSION The method was simple,sensitive,accurate,and good accuracy.It can be used for the determination of ropisentron hydrochloride.

About this research paper

What this paper is about

OBJECTIVE The content determination of ropisentron hydrochloride in tropisentron Hydrochloride and sodium chloride injection by RP-HPLC.METHODS Column was used with octadecyl silane boned silica gel as filler.The mobile phase was Methanol-water-acetonitrile-triethylamine(62∶26∶12∶0.2).The detection wavelength was 284nm.RESULTS Ropisentron hydrochloride showed a good linear relationship in the range of 2~40μg·mL-1(Y=15.623X+8.16,r=0.9997)and the average recovery was 99.72%,RSD was 0.63%.CONCLUSION The method was simple,sensitive,accurate,and good accuracy.It can be used for the determination of ropisentron hydrochloride.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE The content determination of ropisentron hydrochloride in tropisentron Hydrochloride and sodium chloride injection by RP-HPLC.METHODS Column was used with octadecyl silane boned silica gel as filler.The mobile phase was Methanol-water-acetonitrile-triethylamine(62∶26∶12∶0.2).The detection wavelength was 284nm.RESULTS Ropisentron hydrochloride showed a good linear relationship in the range of 2~40μg·mL-1(Y=15.623X+8.16,r=0.9997)and the average recovery was 99.72%,RSD was 0.63%.CONCLUSION The method was simple,sensitive,accurate,and good accuracy.It can be used for the determination of ropisentron hydrochloride.

Key concepts: Chromatography, Chemistry, Triethylamine, High-performance liquid chromatography, Hydrochloride, Sodium, Silica gel, Content determination

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of ropisentron hydrochloride in Tropisentron Hydrochloride and Sodium Chloride Injection by HPLC — Research Paper | ScholarLens