2001ZhongchengyaoRequires access

Determination of Acetamidopyrrolidone in Compound Huonaosu Capsules by RP-HPLC

Chun Hua Zhao

Open publisher page 0 citations

Abstract

Objective: To establish the determination method of acetamidopyrrolidone in Compound Huonaosu Capsules with RP HPLC. Methods: Kromasil C 18 column was used. The mobile phase was methanol water(10∶90) with 0.6ml·min -1 of flow rate, and the detection wavelength was at 230nm. Results: The linear range of acetamidopyrrolidone concentration was from 0.17 to 0.78mg·ml -1 and correlation coefficient was 0.9995. The average recovery of sample was 99.9% and RSD and 0.62%(n=5). Conclusion: The method is simple, accurate and reproducible. It can be used for determination of acetamidopyrrolidone Compound in Huonaosu Capsules.

About this research paper

What this paper is about

Objective: To establish the determination method of acetamidopyrrolidone in Compound Huonaosu Capsules with RP HPLC. Methods: Kromasil C 18 column was used. The mobile phase was methanol water(10∶90) with 0.6ml·min -1 of flow rate, and the detection wavelength was at 230nm. Results: The linear range of acetamidopyrrolidone concentration was from 0.17 to 0.78mg·ml -1 and correlation coefficient was 0.9995. The average recovery of sample was 99.9% and RSD and 0.62%(n=5). Conclusion: The method is simple, accurate and reproducible. It can be used for determination of acetamidopyrrolidone Compound in Huonaosu Capsules.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective: To establish the determination method of acetamidopyrrolidone in Compound Huonaosu Capsules with RP HPLC. Methods: Kromasil C 18 column was used. The mobile phase was methanol water(10∶90) with 0.6ml·min -1 of flow rate, and the detection wavelength was at 230nm. Results: The linear range of acetamidopyrrolidone concentration was from 0.17 to 0.78mg·ml -1 and correlation coefficient was 0.9995. The average recovery of sample was 99.9% and RSD and 0.62%(n=5). Conclusion: The method is simple, accurate and reproducible. It can be used for determination of acetamidopyrrolidone Compound in Huonaosu Capsules.

Key concepts: Chromatography, Correlation coefficient, Chemistry, High-performance liquid chromatography, Linear correlation, Linear relationship, Linear range, Coefficient of variation

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Acetamidopyrrolidone in Compound Huonaosu Capsules by RP-HPLC — Research Paper | ScholarLens