2007•Traditional Chinese MedicineRequires access

Determination of Paeoniflorn in naoxueshuan Capsules by HPLC

LI Aiting

Open publisher page 0 citations

Abstract

Objective To establish a RP-HPLC method for quantitative determination of Paeoniflorn in naoxueshuan Capsules.Methods The separation was performed on Dikma C18 column(4.6 mm×150 mm,5μm) with mobile phase of Acetonitrile and Water(14:86) at a flow rate of 1.0 mL/min.The UV detection wavelength was 230 nm.Results The linear range of Paeoniflorn was 0.156~0.364 μg,r=0.9999.The mean recovery was 98.32 %,RSD 0.83 %(n=5).Conclusion This method is simple,accurate,sensitive and with good reproducibility.

About this research paper

What this paper is about

Objective To establish a RP-HPLC method for quantitative determination of Paeoniflorn in naoxueshuan Capsules.Methods The separation was performed on Dikma C18 column(4.6 mm×150 mm,5μm) with mobile phase of Acetonitrile and Water(14:86) at a flow rate of 1.0 mL/min.The UV detection wavelength was 230 nm.Results The linear range of Paeoniflorn was 0.156~0.364 μg,r=0.9999.The mean recovery was 98.32 %,RSD 0.83 %(n=5).Conclusion This method is simple,accurate,sensitive and with good reproducibility.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a RP-HPLC method for quantitative determination of Paeoniflorn in naoxueshuan Capsules.Methods The separation was performed on Dikma C18 column(4.6 mm×150 mm,5μm) with mobile phase of Acetonitrile and Water(14:86) at a flow rate of 1.0 mL/min.The UV detection wavelength was 230 nm.Results The linear range of Paeoniflorn was 0.156~0.364 μg,r=0.9999.The mean recovery was 98.32 %,RSD 0.83 %(n=5).Conclusion This method is simple,accurate,sensitive and with good reproducibility.

Key concepts: Chromatography, Reproducibility, High-performance liquid chromatography, Linear range, Acetonitrile, Linear relationship, Chemistry, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Paeoniflorn in naoxueshuan Capsules by HPLC — Research Paper | ScholarLens