[Rapid determination of chlorogenic acid in aqueous solution of Flos Lonicerae Japonicae extraction].

Na Li, Xiaoyan Gao, Qiang Fan, Yanjiang Qiao

Open publisher page 2 citations

Abstract

OBJECTIVE: To establish a rapid method for the determination of chlorogenic acid in aqueous solution of Flos Lonicerae Japonicae extraction. METHOD: Chlorogenic acid content in aqueous solution of Flos Lonicerae Japonicae extraction was measured by RP-HPLC. The UV spectrum of the same samples were scanned simultaneously. The wavelength of the best correlation between UV absorbance and chlorogenic acid content determined by HPLC was chosen and the chlorogenic acid content of aqueous solution of Flos Lonicerae Japonicae extraction was estimated by prediction equation. Other 10 batches of aqueous solution of Flos Lonicerae Japonicae extraction was used for testing the equation by comparison of the values of chlorogenic acid content determined by HPLC and equation. RESULT: Good linearity of chlorogenic acid was obtained within the range of 0.09-2.25 microg by HPLC; The recovery was 100.4%; RSD was 1.1% (n = 5). The best wavelength in UV spectrum correlating with chlorogenic acid content was 294 nm. The prediction equation: chlorogenic acid content C = 2.703 425A(294 nm) - 0.129 18; Good correlation between chlorogenic acid content determined by HPLC and predicted results was found (r = 0.995 2, n = 11). RSD was 0.2% (n = 6). CONCLUSION: This method is simple, rapid and accurate for determination of chlorogenic acid and can be used for the rapid control of aqueous solution of Flos Lonicerae Japonicae extraction.

About this research paper

What this paper is about

OBJECTIVE: To establish a rapid method for the determination of chlorogenic acid in aqueous solution of Flos Lonicerae Japonicae extraction. METHOD: Chlorogenic acid content in aqueous solution of Flos Lonicerae Japonicae extraction was measured by RP-HPLC. The UV spectrum of the same samples were scanned simultaneously. The wavelength of the best correlation between UV absorbance and chlorogenic acid content determined by HPLC was chosen and the chlorogenic acid content of aqueous solution of Flos Lonicerae Japonicae extraction was estimated by prediction equation. Other 10 batches of aqueous solution of Flos Lonicerae Japonicae extraction was used for testing the equation by comparison of the values of chlorogenic acid content determined by HPLC and equation. RESULT: Good linearity of chlorogenic acid was obtained within the range of 0.09-2.25 microg by HPLC; The recovery was 100.4%; RSD was 1.1% (n = 5). The best wavelength in UV spectrum correlating with chlorogenic acid content was 294 nm. The prediction equation: chlorogenic acid content C = 2.703 425A(294 nm) - 0.129 18; Good correlation between chlorogenic acid content determined by HPLC and predicted results was found (r = 0.995 2, n = 11). RSD was 0.2% (n = 6). CONCLUSION: This method is simple, rapid and accurate for determination of chlorogenic acid and can be used for the rapid control of aqueous solution of Flos Lonicerae Japonicae extraction.

Why it matters

OpenAlex reports 2 citations for this work. Citation counts describe recorded attention and do not establish research quality.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE: To establish a rapid method for the determination of chlorogenic acid in aqueous solution of Flos Lonicerae Japonicae extraction. METHOD: Chlorogenic acid content in aqueous solution of Flos Lonicerae Japonicae extraction was measured by RP-HPLC. The UV spectrum of the same samples were scanned simultaneously. The wavelength of the best correlation between UV absorbance and chlorogenic acid content determined by HPLC was chosen and the chlorogenic acid content of aqueous solution of Flos Lonicerae Japonicae extraction was estimated by prediction equation. Other 10 batches of aqueous solution of Flos Lonicerae Japonicae extraction was used for testing the equation by comparison of the values of chlorogenic acid content determined by HPLC and equation. RESULT: Good linearity of chlorogenic acid was obtained within the range of 0.09-2.25 microg by HPLC; The recovery was 100.4%; RSD was 1.1% (n = 5). The best wavelength in UV spectrum correlating with chlorogenic acid content was 294 nm. The prediction equation: chlorogenic acid content C = 2.703 425A(294 nm) - 0.129 18; Good correlation between chlorogenic acid content determined by HPLC and predicted results was found (r = 0.995 2, n = 11). RSD was 0.2% (n = 6). CONCLUSION: This method is simple, rapid and accurate for determination of chlorogenic acid and can be used for the rapid control of aqueous solution of Flos Lonicerae Japonicae extraction.

Key concepts: Chlorogenic acid, Flos, Chemistry, Chromatography, High-performance liquid chromatography, Extraction (chemistry), Aqueous solution, Absorbance

Related papers

Back to paper searchBrowse research topicsOriginal source
[Rapid determination of chlorogenic acid in aqueous solution of Flos Lonicerae Japonicae extraction]. — Research Paper | ScholarLens