2008Journal of Jilin University(Science Edition)Requires access

Determination of Chlorogenic Acid in Flos Lonicerae Japonicae via Dynamic Microwave-assisted Extraction Coupled On-line with High-performance Liquid Chromatography

Hanqi Zhang

Open publisher page 0 citations

Abstract

A fast method based on dynamic microwave-assisted extraction(DMAE) coupled on-line with high-performance liquid chromatography(HPLC) by means of a flow injection interface has been developed for the determination of chlorogenic acid in Flos Lonicerae japonicae. The extraction was performed in a recirculating system.When a number of extraction cycles were completed,the fractional extract(20 μL) was driven to the analytical column by mobile phase and was measured by a UV detector.The extraction conditions were examined and optimized.The detection and quantification limits of chlorogenic acid obtained at optimized conditions are 0.25 and 0.83 μg/mL,respectively.The intra-day and inter-day precisions(RSD) obtained are 3.4% and 4.1%,respectively.The mean recovery of chlorogenic acid is 98.1%.Compared with ultrasonic extraction used in the Chinese pharmacopoeia,the proposed method reduces the amount of solvent, provides more rapid measurement and high extraction yield.

About this research paper

What this paper is about

A fast method based on dynamic microwave-assisted extraction(DMAE) coupled on-line with high-performance liquid chromatography(HPLC) by means of a flow injection interface has been developed for the determination of chlorogenic acid in Flos Lonicerae japonicae. The extraction was performed in a recirculating system.When a number of extraction cycles were completed,the fractional extract(20 μL) was driven to the analytical column by mobile phase and was measured by a UV detector.The extraction conditions were examined and optimized.The detection and quantification limits of chlorogenic acid obtained at optimized conditions are 0.25 and 0.83 μg/mL,respectively.The intra-day and inter-day precisions(RSD) obtained are 3.4% and 4.1%,respectively.The mean recovery of chlorogenic acid is 98.1%.Compared with ultrasonic extraction used in the Chinese pharmacopoeia,the proposed method reduces the amount of solvent, provides more rapid measurement and high extraction yield.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

A fast method based on dynamic microwave-assisted extraction(DMAE) coupled on-line with high-performance liquid chromatography(HPLC) by means of a flow injection interface has been developed for the determination of chlorogenic acid in Flos Lonicerae japonicae. The extraction was performed in a recirculating system.When a number of extraction cycles were completed,the fractional extract(20 μL) was driven to the analytical column by mobile phase and was measured by a UV detector.The extraction conditions were examined and optimized.The detection and quantification limits of chlorogenic acid obtained at optimized conditions are 0.25 and 0.83 μg/mL,respectively.The intra-day and inter-day precisions(RSD) obtained are 3.4% and 4.1%,respectively.The mean recovery of chlorogenic acid is 98.1%.Compared with ultrasonic extraction used in the Chinese pharmacopoeia,the proposed method reduces the amount of solvent, provides more rapid measurement and high extraction yield.

Key concepts: Flos, Chlorogenic acid, Chromatography, Extraction (chemistry), High-performance liquid chromatography, Chemistry, Solvent, Rutin

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Chlorogenic Acid in Flos Lonicerae Japonicae via Dynamic Microwave-assisted Extraction Coupled On-line with High-performance Liquid Chromatography — Research Paper | ScholarLens