2013Practical Journal of Clinical MedicineRequires access

The verification of abnormal whole blood cell classification with the Sysmex XE-2100 automated hematology analyzer

Zeng Jin-chen

Open publisher page 0 citations

Abstract

Objective To verify the accuracy of abnormal warning of the Sysmex XE-2100 automated hematology analyzer for whole blood cell count and classification.Methods Three hundred eighty-nine samples,which were determined to be abnormal by the analyzer,were stained and optical examined with microscope,and then the results were compared between the two methods.Results The sensitivity(%) of microscopic examination for classification of atypical lymphocyte(ATYP),nucleated red blood cell(NRBC),increase or decrease in mononuclear cells(M),immature granulocyte(IG),white blood cell count(WBC),lymphocyte count(L),microerythrocyte(MICRO) and macro-erythrocyte(MACRO) were 71.79,90.91,78.57,91.03,95.00,96.55 and 100.00,respectively,while the specificity(%) were 94.29,98.41,98.06,91.03,99.31,99.44 and 99.13,respectively.Conclusions The microscopic examination based on the IP information provided by the Sysmex XE-2100 and the information of patients can accurately screen positive samples.The combination of the two methods can provide timely,accurate,and reliable laboratory data for the clinicians.

About this research paper

What this paper is about

Objective To verify the accuracy of abnormal warning of the Sysmex XE-2100 automated hematology analyzer for whole blood cell count and classification.Methods Three hundred eighty-nine samples,which were determined to be abnormal by the analyzer,were stained and optical examined with microscope,and then the results were compared between the two methods.Results The sensitivity(%) of microscopic examination for classification of atypical lymphocyte(ATYP),nucleated red blood cell(NRBC),increase or decrease in mononuclear cells(M),immature granulocyte(IG),white blood cell count(WBC),lymphocyte count(L),microerythrocyte(MICRO) and macro-erythrocyte(MACRO) were 71.79,90.91,78.57,91.03,95.00,96.55 and 100.00,respectively,while the specificity(%) were 94.29,98.41,98.06,91.03,99.31,99.44 and 99.13,respectively.Conclusions The microscopic examination based on the IP information provided by the Sysmex XE-2100 and the information of patients can accurately screen positive samples.The combination of the two methods can provide timely,accurate,and reliable laboratory data for the clinicians.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To verify the accuracy of abnormal warning of the Sysmex XE-2100 automated hematology analyzer for whole blood cell count and classification.Methods Three hundred eighty-nine samples,which were determined to be abnormal by the analyzer,were stained and optical examined with microscope,and then the results were compared between the two methods.Results The sensitivity(%) of microscopic examination for classification of atypical lymphocyte(ATYP),nucleated red blood cell(NRBC),increase or decrease in mononuclear cells(M),immature granulocyte(IG),white blood cell count(WBC),lymphocyte count(L),microerythrocyte(MICRO) and macro-erythrocyte(MACRO) were 71.79,90.91,78.57,91.03,95.00,96.55 and 100.00,respectively,while the specificity(%) were 94.29,98.41,98.06,91.03,99.31,99.44 and 99.13,respectively.Conclusions The microscopic examination based on the IP information provided by the Sysmex XE-2100 and the information of patients can accurately screen positive samples.The combination of the two methods can provide timely,accurate,and reliable laboratory data for the clinicians.

Key concepts: Hematology analyzer, Medicine, White blood cell, Lymphocyte, Nucleated Red Blood Cell, Blood cell, Pathology, Atypical Lymphocyte

Related papers

Back to paper searchBrowse research topicsOriginal source
The verification of abnormal whole blood cell classification with the Sysmex XE-2100 automated hematology analyzer — Research Paper | ScholarLens