The verification of abnormal whole blood cell classification with the Sysmex XE-2100 automated hematology analyzer
Zeng Jin-chen
Abstract
Zeng Jin-chen
Abstract
Objective To verify the accuracy of abnormal warning of the Sysmex XE-2100 automated hematology analyzer for whole blood cell count and classification.Methods Three hundred eighty-nine samples,which were determined to be abnormal by the analyzer,were stained and optical examined with microscope,and then the results were compared between the two methods.Results The sensitivity(%) of microscopic examination for classification of atypical lymphocyte(ATYP),nucleated red blood cell(NRBC),increase or decrease in mononuclear cells(M),immature granulocyte(IG),white blood cell count(WBC),lymphocyte count(L),microerythrocyte(MICRO) and macro-erythrocyte(MACRO) were 71.79,90.91,78.57,91.03,95.00,96.55 and 100.00,respectively,while the specificity(%) were 94.29,98.41,98.06,91.03,99.31,99.44 and 99.13,respectively.Conclusions The microscopic examination based on the IP information provided by the Sysmex XE-2100 and the information of patients can accurately screen positive samples.The combination of the two methods can provide timely,accurate,and reliable laboratory data for the clinicians.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To verify the accuracy of abnormal warning of the Sysmex XE-2100 automated hematology analyzer for whole blood cell count and classification.Methods Three hundred eighty-nine samples,which were determined to be abnormal by the analyzer,were stained and optical examined with microscope,and then the results were compared between the two methods.Results The sensitivity(%) of microscopic examination for classification of atypical lymphocyte(ATYP),nucleated red blood cell(NRBC),increase or decrease in mononuclear cells(M),immature granulocyte(IG),white blood cell count(WBC),lymphocyte count(L),microerythrocyte(MICRO) and macro-erythrocyte(MACRO) were 71.79,90.91,78.57,91.03,95.00,96.55 and 100.00,respectively,while the specificity(%) were 94.29,98.41,98.06,91.03,99.31,99.44 and 99.13,respectively.Conclusions The microscopic examination based on the IP information provided by the Sysmex XE-2100 and the information of patients can accurately screen positive samples.The combination of the two methods can provide timely,accurate,and reliable laboratory data for the clinicians.
Key concepts: Hematology analyzer, Medicine, White blood cell, Lymphocyte, Nucleated Red Blood Cell, Blood cell, Pathology, Atypical Lymphocyte