Comparison between ECLIA and DELFIA for determination of thyroid hormone levels and the correction method for differences
Liu Ying, Deng Zhiyong, LI Jin-qian, An Zhenhai
Abstract
Liu Ying, Deng Zhiyong, LI Jin-qian, An Zhenhai
Abstract
To compare the determination results by ECLIA and DELFIA for thyroid hormone levels, to establish a method of difference correction,and to set up a quality control system for these two instruments, 77 blood samples were collected and T3 ,T4 ,TSH,FT3 and FT4 levels were determined by E170 ECLIA and Auto DELFIA 1235. The results between the two instruments were analyzed by paired t-test. There were significant differences in results of T3 , T4 , FT3 and FT4 (P0. 05) ;but the results of TSH were concordant(P0. 05). For the results of T3, T4, TSH, FT3 and FT4 analyzed by linear regression, the correlation coefficients between these two instruments were r0. 970. The correlation analysis showed P0. 05. It is indicated that the correlation was good between these two instruments. The results of T3, T4, FT3 and FT4 by these two instruments showed different, but the results of TSH were concordant. The best method to eliminate differences between the results determined by these two instruments may be establishing a correction method.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
To compare the determination results by ECLIA and DELFIA for thyroid hormone levels, to establish a method of difference correction,and to set up a quality control system for these two instruments, 77 blood samples were collected and T3 ,T4 ,TSH,FT3 and FT4 levels were determined by E170 ECLIA and Auto DELFIA 1235. The results between the two instruments were analyzed by paired t-test. There were significant differences in results of T3 , T4 , FT3 and FT4 (P0. 05) ;but the results of TSH were concordant(P0. 05). For the results of T3, T4, TSH, FT3 and FT4 analyzed by linear regression, the correlation coefficients between these two instruments were r0. 970. The correlation analysis showed P0. 05. It is indicated that the correlation was good between these two instruments. The results of T3, T4, FT3 and FT4 by these two instruments showed different, but the results of TSH were concordant. The best method to eliminate differences between the results determined by these two instruments may be establishing a correction method.
Key concepts: Medicine, Hormone, Correlation, Thyroid, Internal medicine, Thyroid-stimulating hormone, Linear correlation, Linear regression