Determination of carbamazepine and carbamazepine-10,11-epoxide in human serum with HPLC
Yulan Zhu
Abstract
Yulan Zhu
Abstract
Objective To develop a method of HPLC to determine carbamazepine and carbamazepine-10,11-epoxide in human serum.Methods Samples were separated on Diamond C18(200 mm×4.6 mm,5 μm).Different ratios of methanol-water were used as the gradient eluent,and flow rate was 1.0 mL·min-1.The column temperature was 25 ℃ and detection wavelength was 215 nm.Intern standard was estazolam.Results The calibration curves were linear in the ranges of 1.08~21.60 μg·mL-1(r=0.9958)and 0.20~5.00 μg·mL-1(r=0.9952) for carbamazepine and carbamazepine-10,11-epoxide respectively;the lowest limits of assay were both 0.10 μg·mL-1.The average recoveries at three concentrations of carbamazepine were(98.5±5.1)%,(103.6±4.8)%,(100.0±4.9)%,and those of carbamazepine-10,11-epoxide were(95.8±3.6%),(99.7±2.9)%,(93.0±5.7)% respectively;RSD of the intra-day and inter-day were less than 10%.Conclusion The method is rapid,sensitive and suitable for determination of carbamazepine and carbamazepine-10,11-epoxide in human serum.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Objective To develop a method of HPLC to determine carbamazepine and carbamazepine-10,11-epoxide in human serum.Methods Samples were separated on Diamond C18(200 mm×4.6 mm,5 μm).Different ratios of methanol-water were used as the gradient eluent,and flow rate was 1.0 mL·min-1.The column temperature was 25 ℃ and detection wavelength was 215 nm.Intern standard was estazolam.Results The calibration curves were linear in the ranges of 1.08~21.60 μg·mL-1(r=0.9958)and 0.20~5.00 μg·mL-1(r=0.9952) for carbamazepine and carbamazepine-10,11-epoxide respectively;the lowest limits of assay were both 0.10 μg·mL-1.The average recoveries at three concentrations of carbamazepine were(98.5±5.1)%,(103.6±4.8)%,(100.0±4.9)%,and those of carbamazepine-10,11-epoxide were(95.8±3.6%),(99.7±2.9)%,(93.0±5.7)% respectively;RSD of the intra-day and inter-day were less than 10%.Conclusion The method is rapid,sensitive and suitable for determination of carbamazepine and carbamazepine-10,11-epoxide in human serum.
Key concepts: Carbamazepine, Chromatography, Chemistry, High-performance liquid chromatography, Epoxide, Medicine, Biochemistry, Psychiatry