2005Anhui Medical and Pharmaceutical JournalRequires access

Determination of Carbamazepine,Carbamazepine-10,11-epoxide in serum by HPLC

LI Guo-zhong

Open publisher page 0 citations

Abstract

AimTo determinecarbamazepine,carbamazepine-10,11-epoxidein serum by high performance liquid chromatography(HPLC).MethodsSerum sample was extracted with 5ml aether, Estazolam was selected as an internal standard, AnUV detector (215 nm)and Kromasil C_(18 )column (150mm4.6mm,5μm)were used. The mobile phase consisted of acetonitrile-water(12).The flow rate was 1.2 mlmin~(-1).ResultsThe linear range of carbamazepine and carbamazepine-10,11-epoxide were 1.0~20.0 mgL~(-1)(r=0.999 9),0.1~5.0 mgL~(-1)(r=0.999 4),.The mean recovery were nearly 100%,.The relative standard deviation(RSD)of inter-day and intra-day for carbamazepine and carbamazepine-10,11-epoxide were less than 5%.ConclusionThe method is accurate,sensitive and more suitable for clinical routine monitoring.

About this research paper

What this paper is about

AimTo determinecarbamazepine,carbamazepine-10,11-epoxidein serum by high performance liquid chromatography(HPLC).MethodsSerum sample was extracted with 5ml aether, Estazolam was selected as an internal standard, AnUV detector (215 nm)and Kromasil C_(18 )column (150mm4.6mm,5μm)were used. The mobile phase consisted of acetonitrile-water(12).The flow rate was 1.2 mlmin~(-1).ResultsThe linear range of carbamazepine and carbamazepine-10,11-epoxide were 1.0~20.0 mgL~(-1)(r=0.999 9),0.1~5.0 mgL~(-1)(r=0.999 4),.The mean recovery were nearly 100%,.The relative standard deviation(RSD)of inter-day and intra-day for carbamazepine and carbamazepine-10,11-epoxide were less than 5%.ConclusionThe method is accurate,sensitive and more suitable for clinical routine monitoring.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AimTo determinecarbamazepine,carbamazepine-10,11-epoxidein serum by high performance liquid chromatography(HPLC).MethodsSerum sample was extracted with 5ml aether, Estazolam was selected as an internal standard, AnUV detector (215 nm)and Kromasil C_(18 )column (150mm4.6mm,5μm)were used. The mobile phase consisted of acetonitrile-water(12).The flow rate was 1.2 mlmin~(-1).ResultsThe linear range of carbamazepine and carbamazepine-10,11-epoxide were 1.0~20.0 mgL~(-1)(r=0.999 9),0.1~5.0 mgL~(-1)(r=0.999 4),.The mean recovery were nearly 100%,.The relative standard deviation(RSD)of inter-day and intra-day for carbamazepine and carbamazepine-10,11-epoxide were less than 5%.ConclusionThe method is accurate,sensitive and more suitable for clinical routine monitoring.

Key concepts: Carbamazepine, Chromatography, High-performance liquid chromatography, Relative standard deviation, Chemistry, Acetonitrile, Detection limit, Medicine

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Carbamazepine,Carbamazepine-10,11-epoxide in serum by HPLC — Research Paper | ScholarLens