2005Research and Practice on Chinese MedicinesRequires access

Determination of Paeoniflorin in Erlongzuoci Pills by HPLC

Zhu Shan-yin

Open publisher page 0 citations

Abstract

Objective To establish the method for determining the content of paeoniflorin in Erlongzuoci Pills by HPLC.Methods The Suntek C 18 column with acetonitrile-water(30∶70 ) as the mobile phase was used.The flow rate was 1.0 mL/min and the detective wavelength was 230 nm.Result The calibration curve was linear at a range of 20~120 μg/mL for paeoniflorin(r=0.999 4).The average recovery was 99.79% and RSD was 1.52% (n=6).Conclusion The method is simple,and accurate with a good reproducibility and can be used as quantitative analysis method for this preparation.

About this research paper

What this paper is about

Objective To establish the method for determining the content of paeoniflorin in Erlongzuoci Pills by HPLC.Methods The Suntek C 18 column with acetonitrile-water(30∶70 ) as the mobile phase was used.The flow rate was 1.0 mL/min and the detective wavelength was 230 nm.Result The calibration curve was linear at a range of 20~120 μg/mL for paeoniflorin(r=0.999 4).The average recovery was 99.79% and RSD was 1.52% (n=6).Conclusion The method is simple,and accurate with a good reproducibility and can be used as quantitative analysis method for this preparation.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish the method for determining the content of paeoniflorin in Erlongzuoci Pills by HPLC.Methods The Suntek C 18 column with acetonitrile-water(30∶70 ) as the mobile phase was used.The flow rate was 1.0 mL/min and the detective wavelength was 230 nm.Result The calibration curve was linear at a range of 20~120 μg/mL for paeoniflorin(r=0.999 4).The average recovery was 99.79% and RSD was 1.52% (n=6).Conclusion The method is simple,and accurate with a good reproducibility and can be used as quantitative analysis method for this preparation.

Key concepts: Paeoniflorin, Chromatography, Calibration curve, High-performance liquid chromatography, Reproducibility, Chemistry, Linear range, Analytical Chemistry (journal)