2007Strait Pharmaceutical JournalRequires access

Determination of paeoniflorin in Baidai pills by HPLC

Yang Min-cong

Open publisher page 0 citations

Abstract

OBJECTIVE To establish a HPLC method for the determination of the contentof Paeoniflorin in Baidai Pills.METHODS Kromasil 100-5C18(250mm×4.6mm)column was used,the mobile phase was methanol,rate was set at 1.0mL·min-1,the detection wave length was 230nm;and column temperature was room temperature.RESULTS The calibration curve was linear(r=0.9999,n=5)in the range of 0.9224~2.244μg for Paeoniflorin,the average recovery was 99.84% RSD was 0.34%(n=9).CONCLUSION This method may be accurate,sample sensitive and reliable and it can be ed as the quality control of Baidai pills.

About this research paper

What this paper is about

OBJECTIVE To establish a HPLC method for the determination of the contentof Paeoniflorin in Baidai Pills.METHODS Kromasil 100-5C18(250mm×4.6mm)column was used,the mobile phase was methanol,rate was set at 1.0mL·min-1,the detection wave length was 230nm;and column temperature was room temperature.RESULTS The calibration curve was linear(r=0.9999,n=5)in the range of 0.9224~2.244μg for Paeoniflorin,the average recovery was 99.84% RSD was 0.34%(n=9).CONCLUSION This method may be accurate,sample sensitive and reliable and it can be ed as the quality control of Baidai pills.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE To establish a HPLC method for the determination of the contentof Paeoniflorin in Baidai Pills.METHODS Kromasil 100-5C18(250mm×4.6mm)column was used,the mobile phase was methanol,rate was set at 1.0mL·min-1,the detection wave length was 230nm;and column temperature was room temperature.RESULTS The calibration curve was linear(r=0.9999,n=5)in the range of 0.9224~2.244μg for Paeoniflorin,the average recovery was 99.84% RSD was 0.34%(n=9).CONCLUSION This method may be accurate,sample sensitive and reliable and it can be ed as the quality control of Baidai pills.

Key concepts: Paeoniflorin, Chromatography, Calibration curve, High-performance liquid chromatography, Chemistry, Analytical Chemistry (journal), Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of paeoniflorin in Baidai pills by HPLC — Research Paper | ScholarLens