Determination of Three Constituents in Ginsenoside-Sodium Chloride Injection By HPLC
Zhao Qing
Abstract
Zhao Qing
Abstract
Aim To establish a method to control the quality of Gisenoside-Sodium chloride injection.Methods The three constituents of ginsenoside Rb 1,ginsenoside Rg 1,notoginsenoside R 1 were determined by HPLC method.Chromatographic conditions included Shim-pack CLC-ODS colun,mobile phase using of Acetonitrile and 0.05% Phosphoric acid (35∶65) for determining ginsenoside Rb 1,Acetonitrile and 0.05% Phosphoric acid (25∶75) for determining ginsenoside Rg 1 and notoginsenoside R 1.The flow rate was 1.5ml/min.Detection wavelength was 203nm.Results A good linearity was obtained respectively in the range of 0.79~3.94μg for ginsenoside Rb 1,0.62~3.21μg for ginsenoside Rg 1 and 0.65~3.57μg for notoginsenoside R 1.The average recovery rates of ginsenoside Rb 1,ginsenoside Rg 1 and notoginsenoside R 1 were 100.14% (RSD=0.73%),99.66% (RSD=0.72%),100.99%(RSD=0.59%),respectively.Conclusion The method appeared to be simple,quick,sensitive,accurate,reproducible and could be used for the quality control of Gisenoside-Sodium chlonide injection.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
Aim To establish a method to control the quality of Gisenoside-Sodium chloride injection.Methods The three constituents of ginsenoside Rb 1,ginsenoside Rg 1,notoginsenoside R 1 were determined by HPLC method.Chromatographic conditions included Shim-pack CLC-ODS colun,mobile phase using of Acetonitrile and 0.05% Phosphoric acid (35∶65) for determining ginsenoside Rb 1,Acetonitrile and 0.05% Phosphoric acid (25∶75) for determining ginsenoside Rg 1 and notoginsenoside R 1.The flow rate was 1.5ml/min.Detection wavelength was 203nm.Results A good linearity was obtained respectively in the range of 0.79~3.94μg for ginsenoside Rb 1,0.62~3.21μg for ginsenoside Rg 1 and 0.65~3.57μg for notoginsenoside R 1.The average recovery rates of ginsenoside Rb 1,ginsenoside Rg 1 and notoginsenoside R 1 were 100.14% (RSD=0.73%),99.66% (RSD=0.72%),100.99%(RSD=0.59%),respectively.Conclusion The method appeared to be simple,quick,sensitive,accurate,reproducible and could be used for the quality control of Gisenoside-Sodium chlonide injection.
Key concepts: Phosphoric acid, Chemistry, Chromatography, Ginsenoside, High-performance liquid chromatography, Sodium, Ginsenoside Rg1, Acetonitrile