2003Pharmaceutical Journal of Chinese People's Liberation ArmyRequires access

Determination of Three Constituents in Ginsenoside-Sodium Chloride Injection By HPLC

Zhao Qing

Open publisher page 0 citations

Abstract

Aim To establish a method to control the quality of Gisenoside-Sodium chloride injection.Methods The three constituents of ginsenoside Rb 1,ginsenoside Rg 1,notoginsenoside R 1 were determined by HPLC method.Chromatographic conditions included Shim-pack CLC-ODS colun,mobile phase using of Acetonitrile and 0.05% Phosphoric acid (35∶65) for determining ginsenoside Rb 1,Acetonitrile and 0.05% Phosphoric acid (25∶75) for determining ginsenoside Rg 1 and notoginsenoside R 1.The flow rate was 1.5ml/min.Detection wavelength was 203nm.Results A good linearity was obtained respectively in the range of 0.79~3.94μg for ginsenoside Rb 1,0.62~3.21μg for ginsenoside Rg 1 and 0.65~3.57μg for notoginsenoside R 1.The average recovery rates of ginsenoside Rb 1,ginsenoside Rg 1 and notoginsenoside R 1 were 100.14% (RSD=0.73%),99.66% (RSD=0.72%),100.99%(RSD=0.59%),respectively.Conclusion The method appeared to be simple,quick,sensitive,accurate,reproducible and could be used for the quality control of Gisenoside-Sodium chlonide injection.

About this research paper

What this paper is about

Aim To establish a method to control the quality of Gisenoside-Sodium chloride injection.Methods The three constituents of ginsenoside Rb 1,ginsenoside Rg 1,notoginsenoside R 1 were determined by HPLC method.Chromatographic conditions included Shim-pack CLC-ODS colun,mobile phase using of Acetonitrile and 0.05% Phosphoric acid (35∶65) for determining ginsenoside Rb 1,Acetonitrile and 0.05% Phosphoric acid (25∶75) for determining ginsenoside Rg 1 and notoginsenoside R 1.The flow rate was 1.5ml/min.Detection wavelength was 203nm.Results A good linearity was obtained respectively in the range of 0.79~3.94μg for ginsenoside Rb 1,0.62~3.21μg for ginsenoside Rg 1 and 0.65~3.57μg for notoginsenoside R 1.The average recovery rates of ginsenoside Rb 1,ginsenoside Rg 1 and notoginsenoside R 1 were 100.14% (RSD=0.73%),99.66% (RSD=0.72%),100.99%(RSD=0.59%),respectively.Conclusion The method appeared to be simple,quick,sensitive,accurate,reproducible and could be used for the quality control of Gisenoside-Sodium chlonide injection.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Aim To establish a method to control the quality of Gisenoside-Sodium chloride injection.Methods The three constituents of ginsenoside Rb 1,ginsenoside Rg 1,notoginsenoside R 1 were determined by HPLC method.Chromatographic conditions included Shim-pack CLC-ODS colun,mobile phase using of Acetonitrile and 0.05% Phosphoric acid (35∶65) for determining ginsenoside Rb 1,Acetonitrile and 0.05% Phosphoric acid (25∶75) for determining ginsenoside Rg 1 and notoginsenoside R 1.The flow rate was 1.5ml/min.Detection wavelength was 203nm.Results A good linearity was obtained respectively in the range of 0.79~3.94μg for ginsenoside Rb 1,0.62~3.21μg for ginsenoside Rg 1 and 0.65~3.57μg for notoginsenoside R 1.The average recovery rates of ginsenoside Rb 1,ginsenoside Rg 1 and notoginsenoside R 1 were 100.14% (RSD=0.73%),99.66% (RSD=0.72%),100.99%(RSD=0.59%),respectively.Conclusion The method appeared to be simple,quick,sensitive,accurate,reproducible and could be used for the quality control of Gisenoside-Sodium chlonide injection.

Key concepts: Phosphoric acid, Chemistry, Chromatography, Ginsenoside, High-performance liquid chromatography, Sodium, Ginsenoside Rg1, Acetonitrile

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Three Constituents in Ginsenoside-Sodium Chloride Injection By HPLC — Research Paper | ScholarLens