AIM To establish a reversed-phase high performance liquid chromatography method for the determination of icariin in Herba Epimedium.METHODS The analysis was performed on ZORBAX Ecilpse XDB-C_(18)(150 mm×4.6mm,5μm) column.The mobile phase consisted of water:acetonitrile(74:26,V/V) at a flow rate of 1.0 mL·min~(-1) and the detection wavelength was 270 nm.The solution concentrations were detected by HPLC with the column temperature of 25℃.RESULTS Under the conditions described,the calibration curve of icariin was linear within the concentration range of 5-50mg·L~(-1)(r=0.9999,n=5).The average recovery was 100.32%.The mean relative standard deviation(RSD) was 0.44%.CONCLUSION The method is simple,accurate and suitable for the determination of icariin in Herba Epimedium.

About this research paper

What this paper is about

AIM To establish a reversed-phase high performance liquid chromatography method for the determination of icariin in Herba Epimedium.METHODS The analysis was performed on ZORBAX Ecilpse XDB-C_(18)(150 mm×4.6mm,5μm) column.The mobile phase consisted of water:acetonitrile(74:26,V/V) at a flow rate of 1.0 mL·min~(-1) and the detection wavelength was 270 nm.The solution concentrations were detected by HPLC with the column temperature of 25℃.RESULTS Under the conditions described,the calibration curve of icariin was linear within the concentration range of 5-50mg·L~(-1)(r=0.9999,n=5).The average recovery was 100.32%.The mean relative standard deviation(RSD) was 0.44%.CONCLUSION The method is simple,accurate and suitable for the determination of icariin in Herba Epimedium.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

AIM To establish a reversed-phase high performance liquid chromatography method for the determination of icariin in Herba Epimedium.METHODS The analysis was performed on ZORBAX Ecilpse XDB-C_(18)(150 mm×4.6mm,5μm) column.The mobile phase consisted of water:acetonitrile(74:26,V/V) at a flow rate of 1.0 mL·min~(-1) and the detection wavelength was 270 nm.The solution concentrations were detected by HPLC with the column temperature of 25℃.RESULTS Under the conditions described,the calibration curve of icariin was linear within the concentration range of 5-50mg·L~(-1)(r=0.9999,n=5).The average recovery was 100.32%.The mean relative standard deviation(RSD) was 0.44%.CONCLUSION The method is simple,accurate and suitable for the determination of icariin in Herba Epimedium.

Key concepts: Icariin, Epimedium, Chromatography, Chemistry, Calibration curve, High-performance liquid chromatography, Relative standard deviation, Analytical Chemistry (journal)

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of icariin in Herba Epimedium by reversed-phase high performance liquid chromatography — Research Paper | ScholarLens