2004China BrewingRequires access

Determinationof cyclamate in the liquor with high-performance liquid chromatography (HPLC) method

Shen Guo-jun

Open publisher page 0 citations

Abstract

The HPLC method was used to determine the cyclamate contents in the liquor. Chromatography column: ODS Hypersil (5μm, 125 mm×4 mm), mobile phase: CH3OH:H2O = 80:20, flow rate: 1.0 mL, detection wavelength: 314 nm. The results showed that linear range 4:μg/mL-100μg/mL, recycling rate: 80.6%-102.7%, RSD: 10.8%-2.5%, lower limit of quantitative detection: 1.2μg/mL, higher limit of quantitative detection: 4.0μg/mL. This method is convenient and reliable, and is suitable for the detection of cyclamate contents in the liquor.

About this research paper

What this paper is about

The HPLC method was used to determine the cyclamate contents in the liquor. Chromatography column: ODS Hypersil (5μm, 125 mm×4 mm), mobile phase: CH3OH:H2O = 80:20, flow rate: 1.0 mL, detection wavelength: 314 nm. The results showed that linear range 4:μg/mL-100μg/mL, recycling rate: 80.6%-102.7%, RSD: 10.8%-2.5%, lower limit of quantitative detection: 1.2μg/mL, higher limit of quantitative detection: 4.0μg/mL. This method is convenient and reliable, and is suitable for the detection of cyclamate contents in the liquor.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

The HPLC method was used to determine the cyclamate contents in the liquor. Chromatography column: ODS Hypersil (5μm, 125 mm×4 mm), mobile phase: CH3OH:H2O = 80:20, flow rate: 1.0 mL, detection wavelength: 314 nm. The results showed that linear range 4:μg/mL-100μg/mL, recycling rate: 80.6%-102.7%, RSD: 10.8%-2.5%, lower limit of quantitative detection: 1.2μg/mL, higher limit of quantitative detection: 4.0μg/mL. This method is convenient and reliable, and is suitable for the detection of cyclamate contents in the liquor.

Key concepts: Chromatography, Detection limit, High-performance liquid chromatography, Chemistry, Linear range, Volumetric flow rate, Quantum mechanics, Physics

Related papers

Back to paper searchBrowse research topicsOriginal source
Determinationof cyclamate in the liquor with high-performance liquid chromatography (HPLC) method — Research Paper | ScholarLens