2013Strait Pharmaceutical JournalRequires access

Determination of Chlorogenic Acid in Jieshitong tablets by HPLC

Guo Zhong-zh

Open publisher page 0 citations

Abstract

OBJECTIVE To establish a High-performance liquid chromatography( HPLC) for determining of Chlorogenic acid in Jieshitong tablets. METHODS Using high performance liquid chromatography,the determination was performed on sinochrom ODS-BP( 4. 6mm × 250mm,5μm) column,mobile phase for acetonitril-e-0. 5%phosphoric acid solution( 8∶ 92),detected wavelength for 326nm,velocity of 1. 0mL·min-1. RESULTS The linear range of Chlorogenic acid was 0. 4024 ~ 3. 2192μg·mL-1( r =0. 9997 n =6),the average recovery was 99. 46%,and the RSD( n = 9) was 0. 82%. CONCLUSION The method is proved to be simple,reproducible and specific,and it's propitious to used for determining of Chlorogenic acid in Jieshitong tablets.

About this research paper

What this paper is about

OBJECTIVE To establish a High-performance liquid chromatography( HPLC) for determining of Chlorogenic acid in Jieshitong tablets. METHODS Using high performance liquid chromatography,the determination was performed on sinochrom ODS-BP( 4. 6mm × 250mm,5μm) column,mobile phase for acetonitril-e-0. 5%phosphoric acid solution( 8∶ 92),detected wavelength for 326nm,velocity of 1. 0mL·min-1. RESULTS The linear range of Chlorogenic acid was 0. 4024 ~ 3. 2192μg·mL-1( r =0. 9997 n =6),the average recovery was 99. 46%,and the RSD( n = 9) was 0. 82%. CONCLUSION The method is proved to be simple,reproducible and specific,and it's propitious to used for determining of Chlorogenic acid in Jieshitong tablets.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE To establish a High-performance liquid chromatography( HPLC) for determining of Chlorogenic acid in Jieshitong tablets. METHODS Using high performance liquid chromatography,the determination was performed on sinochrom ODS-BP( 4. 6mm × 250mm,5μm) column,mobile phase for acetonitril-e-0. 5%phosphoric acid solution( 8∶ 92),detected wavelength for 326nm,velocity of 1. 0mL·min-1. RESULTS The linear range of Chlorogenic acid was 0. 4024 ~ 3. 2192μg·mL-1( r =0. 9997 n =6),the average recovery was 99. 46%,and the RSD( n = 9) was 0. 82%. CONCLUSION The method is proved to be simple,reproducible and specific,and it's propitious to used for determining of Chlorogenic acid in Jieshitong tablets.

Key concepts: Chlorogenic acid, Phosphoric acid, Chromatography, High-performance liquid chromatography, Chemistry, Linear relationship, Linear range, Detection limit

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Chlorogenic Acid in Jieshitong tablets by HPLC — Research Paper | ScholarLens