2015Medical Journal of West ChinaRequires access

High-frequency ultrasound and X-ray mammography in early breastcancer screening

Tang Ron

Open publisher page 0 citations

Abstract

Objective To explore the clinical value of the high-frequency ultrasound and X-ray mammography screening applied to the early diagnosis of breast cancer.Methods A retrospective analysis of 126 patients with pathologically confirmed breast cancer(diameter2cm)medical records of patients.With pathological findings as the gold standard,high-frequency ultrasound,X-ray mammography and their combination for early screening results with pathological results of a comparative analysis of breast cancer.Results High-frequency ultrasound and X-ray diagnosis of breast cancer mammography compliance rates were 82.3%,80.2%,there was no significant difference between them(P0.05);their combination diagnosis was 97.5%,with a single inspection methods comparison,there was a statistically significant difference between groups(P0.05).High-frequency ultrasound for micro calcification detection rate(33.7%)was lower than X-ray mammography(60.3%),while the flow signal detection rate of breast cancer(80.4%)was higher than X-ray mammography(22.6%),there was group statistically significant difference between(P 0.05).Conclusion High-frequency ultrasound,X-ray mammography screening for breast cancer early have their own advantages,the combination can significantly improve the accuracy of diagnosis of breast cancer,with a high clinical value.

About this research paper

What this paper is about

Objective To explore the clinical value of the high-frequency ultrasound and X-ray mammography screening applied to the early diagnosis of breast cancer.Methods A retrospective analysis of 126 patients with pathologically confirmed breast cancer(diameter2cm)medical records of patients.With pathological findings as the gold standard,high-frequency ultrasound,X-ray mammography and their combination for early screening results with pathological results of a comparative analysis of breast cancer.Results High-frequency ultrasound and X-ray diagnosis of breast cancer mammography compliance rates were 82.3%,80.2%,there was no significant difference between them(P0.05);their combination diagnosis was 97.5%,with a single inspection methods comparison,there was a statistically significant difference between groups(P0.05).High-frequency ultrasound for micro calcification detection rate(33.7%)was lower than X-ray mammography(60.3%),while the flow signal detection rate of breast cancer(80.4%)was higher than X-ray mammography(22.6%),there was group statistically significant difference between(P 0.05).Conclusion High-frequency ultrasound,X-ray mammography screening for breast cancer early have their own advantages,the combination can significantly improve the accuracy of diagnosis of breast cancer,with a high clinical value.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To explore the clinical value of the high-frequency ultrasound and X-ray mammography screening applied to the early diagnosis of breast cancer.Methods A retrospective analysis of 126 patients with pathologically confirmed breast cancer(diameter2cm)medical records of patients.With pathological findings as the gold standard,high-frequency ultrasound,X-ray mammography and their combination for early screening results with pathological results of a comparative analysis of breast cancer.Results High-frequency ultrasound and X-ray diagnosis of breast cancer mammography compliance rates were 82.3%,80.2%,there was no significant difference between them(P0.05);their combination diagnosis was 97.5%,with a single inspection methods comparison,there was a statistically significant difference between groups(P0.05).High-frequency ultrasound for micro calcification detection rate(33.7%)was lower than X-ray mammography(60.3%),while the flow signal detection rate of breast cancer(80.4%)was higher than X-ray mammography(22.6%),there was group statistically significant difference between(P 0.05).Conclusion High-frequency ultrasound,X-ray mammography screening for breast cancer early have their own advantages,the combination can significantly improve the accuracy of diagnosis of breast cancer,with a high clinical value.

Key concepts: Medicine, Mammography, Breast cancer, Ultrasound, Radiology, Pathological, Calcification, Cancer

Related papers

Back to paper searchBrowse research topicsOriginal source
High-frequency ultrasound and X-ray mammography in early breastcancer screening — Research Paper | ScholarLens