Determination of 3-methylindole by High Performance Liquid Chromatography
Zhang Na
Abstract
Zhang Na
Abstract
A HPLC method was established for the determination of 3-methylindole,which consisted of a Hypersill BDS C18 column(4.6 mm ×200 mm,5um) and methanol-water(85:15 v/v) mixture as mobile phase,detected at 254 nm with flow rate of 1.0 ml/min.The linear range was 2-14 ug(r= 0.9996) and the average recovery was 98.9~(99.9%),with RSD of 0.49%.
A significance statement is not available in the OpenAlex record.
A contribution statement is not available in the OpenAlex record.
Method details are not available in the OpenAlex metadata.
Findings are not separately available in the OpenAlex metadata.
Limitations are not available in the OpenAlex metadata.
Application details are not available in the OpenAlex metadata.
A HPLC method was established for the determination of 3-methylindole,which consisted of a Hypersill BDS C18 column(4.6 mm ×200 mm,5um) and methanol-water(85:15 v/v) mixture as mobile phase,detected at 254 nm with flow rate of 1.0 ml/min.The linear range was 2-14 ug(r= 0.9996) and the average recovery was 98.9~(99.9%),with RSD of 0.49%.
Key concepts: Chromatography, High-performance liquid chromatography, Chemistry, Methanol, Volumetric flow rate, Linear range, Phase (matter), Chromatography column