2013•Drug Evaluation ResearchRequires access

Determination of tortoside A in Maozhiqing Oral Liquid by HPLC

Shijie Liu

Open publisher page 0 citations

Abstract

Objective To establish a method for the determination of tortoside A in Maozhiqing Oral Liquid (MOL). Methods The tortoside A was determined by high performance liquid chromatography (HPLC). The Venusil MP C18 column (4.6 mm × 250 mm, 5 μm) was used, the mobile phase was acetonitrile-water (18:82), the detection wavelength was 207 nm, the flow rate was 1.0 mL/min, and the column temperature was 30 ℃. Results Tortoside A has a good linear relationship with the peak area within the range of 1.76 —88.00 μg/mL with an regression equation Y = 83 335X-47 442 (r = 0.999 7). The average recovery was 101.53%, and RSD was 2.50%. Conclusion The established method of HPLC could be used for the quality control of MOL for its simplicity, accuracy, high sensitivity, and good reproducibility.

About this research paper

What this paper is about

Objective To establish a method for the determination of tortoside A in Maozhiqing Oral Liquid (MOL). Methods The tortoside A was determined by high performance liquid chromatography (HPLC). The Venusil MP C18 column (4.6 mm × 250 mm, 5 μm) was used, the mobile phase was acetonitrile-water (18:82), the detection wavelength was 207 nm, the flow rate was 1.0 mL/min, and the column temperature was 30 ℃. Results Tortoside A has a good linear relationship with the peak area within the range of 1.76 —88.00 μg/mL with an regression equation Y = 83 335X-47 442 (r = 0.999 7). The average recovery was 101.53%, and RSD was 2.50%. Conclusion The established method of HPLC could be used for the quality control of MOL for its simplicity, accuracy, high sensitivity, and good reproducibility.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a method for the determination of tortoside A in Maozhiqing Oral Liquid (MOL). Methods The tortoside A was determined by high performance liquid chromatography (HPLC). The Venusil MP C18 column (4.6 mm × 250 mm, 5 μm) was used, the mobile phase was acetonitrile-water (18:82), the detection wavelength was 207 nm, the flow rate was 1.0 mL/min, and the column temperature was 30 ℃. Results Tortoside A has a good linear relationship with the peak area within the range of 1.76 —88.00 μg/mL with an regression equation Y = 83 335X-47 442 (r = 0.999 7). The average recovery was 101.53%, and RSD was 2.50%. Conclusion The established method of HPLC could be used for the quality control of MOL for its simplicity, accuracy, high sensitivity, and good reproducibility.

Key concepts: Chromatography, High-performance liquid chromatography, Reproducibility, Chemistry, Acetonitrile, Linear relationship, Analytical Chemistry (journal), Volumetric flow rate

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of tortoside A in Maozhiqing Oral Liquid by HPLC — Research Paper | ScholarLens