2008Zhongguo yiyuan yongyao pingjia yu fenxiRequires access

Determination of Baicalin in Dahuangling'e Granules by HPLC

Min Xu

Open publisher page 0 citations

Abstract

OBJECTIVE:A HPLC method for the determination of a baicalin in Dahuanglinge Granules was established.METHODS:Nova-pakC18(250 mm×4.6 mm,10 μm)column Was used with methanol-water-0.2% phosphoric acid (47∶53∶0.2) as mobile phase.Content Was detected at a wavelength of 280 nm with the column temperature at 25℃ and flow rate 1 mL·min~ -1 . RESULTS: The linear range was 4~20 μg·mL~ -1 for baicalin with r=0.999 8. The average recovery rate was 98.8%,RSD=1.5% (n=5) for baicalin.CONCLUSION:The method Was simple and accurate.The result is stable.

About this research paper

What this paper is about

OBJECTIVE:A HPLC method for the determination of a baicalin in Dahuanglinge Granules was established.METHODS:Nova-pakC18(250 mm×4.6 mm,10 μm)column Was used with methanol-water-0.2% phosphoric acid (47∶53∶0.2) as mobile phase.Content Was detected at a wavelength of 280 nm with the column temperature at 25℃ and flow rate 1 mL·min~ -1 . RESULTS: The linear range was 4~20 μg·mL~ -1 for baicalin with r=0.999 8. The average recovery rate was 98.8%,RSD=1.5% (n=5) for baicalin.CONCLUSION:The method Was simple and accurate.The result is stable.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE:A HPLC method for the determination of a baicalin in Dahuanglinge Granules was established.METHODS:Nova-pakC18(250 mm×4.6 mm,10 μm)column Was used with methanol-water-0.2% phosphoric acid (47∶53∶0.2) as mobile phase.Content Was detected at a wavelength of 280 nm with the column temperature at 25℃ and flow rate 1 mL·min~ -1 . RESULTS: The linear range was 4~20 μg·mL~ -1 for baicalin with r=0.999 8. The average recovery rate was 98.8%,RSD=1.5% (n=5) for baicalin.CONCLUSION:The method Was simple and accurate.The result is stable.

Key concepts: Baicalin, Chromatography, Phosphoric acid, High-performance liquid chromatography, Chemistry, Linear range, Recovery rate, Linear relationship

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of Baicalin in Dahuangling'e Granules by HPLC — Research Paper | ScholarLens