2009Zhongguo yixue yingxiang jishuRequires access

Perfusion assessment of living donor kidney with 64-slice spiral CT

He Wen

Open publisher page 0 citations

Abstract

Objective To observe the features and normal ranges of CT perfusion parameters of the living donor kidney with 64-slice spiral CT, and to compare the findings with renal radionuclide imaging and biochemical tests. Methods All of 53 donors underwent CT perfusion scanning, and the values of perfusion parameters of renal cortex including BV (blood volume), BF (blood flow), MTT (mean transit time), PS (permeability surface) and TDC (time density curve) were measured at AW 4.3 workstation with CT Perfusion 3.0 software. Results TDC of all the donors were similar and perfusion parameters of bilateral kidney were basically the same. The mean value of cortex perfusion parameters of left and right kidney were as follows, i.e. BV:(24.55±5.12)ml/100 g,(24.77±4.53)ml/100 g; BF: (498.21±115.59) ml/(100 g·min),(499.47±108.91)ml/(100 g·min); MTT:(3.54±1.08)s,(3.53±1.12)s; and PS:(59.42±12.00)ml/(100 g·min), (59.95±10.80)ml/(100 g·min). The normal ranges of cortex perfusion parameters of left and right kidney were: BV:14.51-34.59 ml/100 g,15.89-33.65 ml/100 g;BF:271.65-724.77 ml/(100 g·min),286.01-712.93 ml/(100 g·min);MTT:1.42-5.66 s,1.33-5.73 s;PS:35.90-82.94 ml/(100 g·min),38.78-81.12 ml/(100 g·min). There was no significant correlation between all perfusion parameters and GFR measured by nuclear method, while some of biochemical parameters were correlated with perfusion parameters. Conclusion 64-slice spiral CT can assess blood perfusion parameters of living donor kidney quantitatively and estimate the normal ranges of CT perfusion parameters of adult renal cortex preliminarily. In healthy adults, there is no significant correlation between all CT perfusion parameters and GFR.

About this research paper

What this paper is about

Objective To observe the features and normal ranges of CT perfusion parameters of the living donor kidney with 64-slice spiral CT, and to compare the findings with renal radionuclide imaging and biochemical tests. Methods All of 53 donors underwent CT perfusion scanning, and the values of perfusion parameters of renal cortex including BV (blood volume), BF (blood flow), MTT (mean transit time), PS (permeability surface) and TDC (time density curve) were measured at AW 4.3 workstation with CT Perfusion 3.0 software. Results TDC of all the donors were similar and perfusion parameters of bilateral kidney were basically the same. The mean value of cortex perfusion parameters of left and right kidney were as follows, i.e. BV:(24.55±5.12)ml/100 g,(24.77±4.53)ml/100 g; BF: (498.21±115.59) ml/(100 g·min),(499.47±108.91)ml/(100 g·min); MTT:(3.54±1.08)s,(3.53±1.12)s; and PS:(59.42±12.00)ml/(100 g·min), (59.95±10.80)ml/(100 g·min). The normal ranges of cortex perfusion parameters of left and right kidney were: BV:14.51-34.59 ml/100 g,15.89-33.65 ml/100 g;BF:271.65-724.77 ml/(100 g·min),286.01-712.93 ml/(100 g·min);MTT:1.42-5.66 s,1.33-5.73 s;PS:35.90-82.94 ml/(100 g·min),38.78-81.12 ml/(100 g·min). There was no significant correlation between all perfusion parameters and GFR measured by nuclear method, while some of biochemical parameters were correlated with perfusion parameters. Conclusion 64-slice spiral CT can assess blood perfusion parameters of living donor kidney quantitatively and estimate the normal ranges of CT perfusion parameters of adult renal cortex preliminarily. In healthy adults, there is no significant correlation between all CT perfusion parameters and GFR.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To observe the features and normal ranges of CT perfusion parameters of the living donor kidney with 64-slice spiral CT, and to compare the findings with renal radionuclide imaging and biochemical tests. Methods All of 53 donors underwent CT perfusion scanning, and the values of perfusion parameters of renal cortex including BV (blood volume), BF (blood flow), MTT (mean transit time), PS (permeability surface) and TDC (time density curve) were measured at AW 4.3 workstation with CT Perfusion 3.0 software. Results TDC of all the donors were similar and perfusion parameters of bilateral kidney were basically the same. The mean value of cortex perfusion parameters of left and right kidney were as follows, i.e. BV:(24.55±5.12)ml/100 g,(24.77±4.53)ml/100 g; BF: (498.21±115.59) ml/(100 g·min),(499.47±108.91)ml/(100 g·min); MTT:(3.54±1.08)s,(3.53±1.12)s; and PS:(59.42±12.00)ml/(100 g·min), (59.95±10.80)ml/(100 g·min). The normal ranges of cortex perfusion parameters of left and right kidney were: BV:14.51-34.59 ml/100 g,15.89-33.65 ml/100 g;BF:271.65-724.77 ml/(100 g·min),286.01-712.93 ml/(100 g·min);MTT:1.42-5.66 s,1.33-5.73 s;PS:35.90-82.94 ml/(100 g·min),38.78-81.12 ml/(100 g·min). There was no significant correlation between all perfusion parameters and GFR measured by nuclear method, while some of biochemical parameters were correlated with perfusion parameters. Conclusion 64-slice spiral CT can assess blood perfusion parameters of living donor kidney quantitatively and estimate the normal ranges of CT perfusion parameters of adult renal cortex preliminarily. In healthy adults, there is no significant correlation between all CT perfusion parameters and GFR.

Key concepts: Perfusion, Medicine, Perfusion scanning, Nuclear medicine, Blood volume, Kidney, Renal cortex, Blood flow

Related papers

Back to paper searchBrowse research topicsOriginal source