2011•Liaoning Zhongyiyao Daxue xuebaoRequires access

Determination of Paeoniflorin in Shaofu Zhuyu Granule by HPLC

Wei Wang

Open publisher page 0 citations

Abstract

Objective:To determine Paeoniflorin in shaofuzhuyu Granule.Methods:Agilent 1100 HPLC and SHIMADZU C18 column(4.6mm×150mm)was eluted,the mobile phase consisted of methanol-water at the column temperature 30℃.The flow rate was 0.9mL/min and detective wavelength was 230nm.Results:Paeoniflorin was proved to be linear in the range of 0.1202~0.7212μg with a regression coefficient of 0.9996.The average recovery was 98.9%(n=6,RSD=0.53%).Conclusion:This method was sensitive,quick and accurate for the quality control of this preparation.

About this research paper

What this paper is about

Objective:To determine Paeoniflorin in shaofuzhuyu Granule.Methods:Agilent 1100 HPLC and SHIMADZU C18 column(4.6mm×150mm)was eluted,the mobile phase consisted of methanol-water at the column temperature 30℃.The flow rate was 0.9mL/min and detective wavelength was 230nm.Results:Paeoniflorin was proved to be linear in the range of 0.1202~0.7212μg with a regression coefficient of 0.9996.The average recovery was 98.9%(n=6,RSD=0.53%).Conclusion:This method was sensitive,quick and accurate for the quality control of this preparation.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective:To determine Paeoniflorin in shaofuzhuyu Granule.Methods:Agilent 1100 HPLC and SHIMADZU C18 column(4.6mm×150mm)was eluted,the mobile phase consisted of methanol-water at the column temperature 30℃.The flow rate was 0.9mL/min and detective wavelength was 230nm.Results:Paeoniflorin was proved to be linear in the range of 0.1202~0.7212μg with a regression coefficient of 0.9996.The average recovery was 98.9%(n=6,RSD=0.53%).Conclusion:This method was sensitive,quick and accurate for the quality control of this preparation.

Key concepts: Paeoniflorin, Granule (geology), Chromatography, Medicine, High-performance liquid chromatography, Composite material, Chemistry, Materials science