2010•Unpublished venueRequires access

Determination the Content of Oleanolic acid in Ganjian capsule by HPLC

Pumc Pharmaceutical

Open publisher page 0 citations

Abstract

Objective To establish the HPLC method for determining the content of Oleanolic acid in Ganjian Capsule.Method The column was Kromasil C-18(250mm×4.6mm,5um) The mobile phase was acetonitrile-water(9:1) the detection wavelength was 210nm the column temperature was 30℃ with the flow rate 0f 1.0ml/min.Results The linear range was 40.16 to 200.8ug/ml for paeonol(r= 0.9998 The recovery was 96.49% and with RSD =0.68% Conclusion The method is accurate and highly reproducible.It can be a method for quality control of Ganjian Capsule.

About this research paper

What this paper is about

Objective To establish the HPLC method for determining the content of Oleanolic acid in Ganjian Capsule.Method The column was Kromasil C-18(250mm×4.6mm,5um) The mobile phase was acetonitrile-water(9:1) the detection wavelength was 210nm the column temperature was 30℃ with the flow rate 0f 1.0ml/min.Results The linear range was 40.16 to 200.8ug/ml for paeonol(r= 0.9998 The recovery was 96.49% and with RSD =0.68% Conclusion The method is accurate and highly reproducible.It can be a method for quality control of Ganjian Capsule.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish the HPLC method for determining the content of Oleanolic acid in Ganjian Capsule.Method The column was Kromasil C-18(250mm×4.6mm,5um) The mobile phase was acetonitrile-water(9:1) the detection wavelength was 210nm the column temperature was 30℃ with the flow rate 0f 1.0ml/min.Results The linear range was 40.16 to 200.8ug/ml for paeonol(r= 0.9998 The recovery was 96.49% and with RSD =0.68% Conclusion The method is accurate and highly reproducible.It can be a method for quality control of Ganjian Capsule.

Key concepts: Chromatography, Oleanolic acid, Capsule, High-performance liquid chromatography, Paeonol, Content determination, Chemistry, Linear range

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination the Content of Oleanolic acid in Ganjian capsule by HPLC — Research Paper | ScholarLens