2009Central South PharmacyRequires access

Content determination of paeoniflorin and ferulic acid in Liuwei Buxue granules by HPLC

Lin Zhou

Open publisher page 0 citations

Abstract

Objective To establish a method for the content determination of paeoniflorin and ferulic acid in Liuwei Buxue granules by HPLC.Methods Ultimate XB-C18 column(250 mm×4.6 mm,5 μm) was used.The mobile phase was acetonitrile-0.1% phosphoric acid solution(15∶85),the detection wavelenghth was 230 nm for paeoniflorin and 323 nm for ferulic acid,the flow rate was 1.0 mL·min-1,and column temperature was 25℃.Results The linear range of paeoniflorin and ferulic acid was 0.108~0.864 μg(r=0.999 6,n=6)and 0.044 0~0.352 μg(r=0.999 8,n=6).The average recovery of paeoniflorin and ferulic acid was 97.77% and 96.78%,RSD(n=9) was 1.33% and 1.08%.Conclusion The method may be used for the content determination of paeoniflorin and ferulic acid in Liuwei Buxue granules.

About this research paper

What this paper is about

Objective To establish a method for the content determination of paeoniflorin and ferulic acid in Liuwei Buxue granules by HPLC.Methods Ultimate XB-C18 column(250 mm×4.6 mm,5 μm) was used.The mobile phase was acetonitrile-0.1% phosphoric acid solution(15∶85),the detection wavelenghth was 230 nm for paeoniflorin and 323 nm for ferulic acid,the flow rate was 1.0 mL·min-1,and column temperature was 25℃.Results The linear range of paeoniflorin and ferulic acid was 0.108~0.864 μg(r=0.999 6,n=6)and 0.044 0~0.352 μg(r=0.999 8,n=6).The average recovery of paeoniflorin and ferulic acid was 97.77% and 96.78%,RSD(n=9) was 1.33% and 1.08%.Conclusion The method may be used for the content determination of paeoniflorin and ferulic acid in Liuwei Buxue granules.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

Objective To establish a method for the content determination of paeoniflorin and ferulic acid in Liuwei Buxue granules by HPLC.Methods Ultimate XB-C18 column(250 mm×4.6 mm,5 μm) was used.The mobile phase was acetonitrile-0.1% phosphoric acid solution(15∶85),the detection wavelenghth was 230 nm for paeoniflorin and 323 nm for ferulic acid,the flow rate was 1.0 mL·min-1,and column temperature was 25℃.Results The linear range of paeoniflorin and ferulic acid was 0.108~0.864 μg(r=0.999 6,n=6)and 0.044 0~0.352 μg(r=0.999 8,n=6).The average recovery of paeoniflorin and ferulic acid was 97.77% and 96.78%,RSD(n=9) was 1.33% and 1.08%.Conclusion The method may be used for the content determination of paeoniflorin and ferulic acid in Liuwei Buxue granules.

Key concepts: Paeoniflorin, Ferulic acid, Chemistry, Chromatography, Phosphoric acid, High-performance liquid chromatography, Content determination, Organic chemistry

Related papers

Back to paper searchBrowse research topicsOriginal source
Content determination of paeoniflorin and ferulic acid in Liuwei Buxue granules by HPLC — Research Paper | ScholarLens