2001Zhōnghuá yàoxué zázhìRequires access

Determination of ferulic acid and paeoniflorin in Xiaoyao Wan by RP-HPLC

Xin Wan

Open publisher page 0 citations

Abstract

OBJECTIVE To develop a method for the determination of ferulic acid and paeoniflorin in Xiaoyao Wan by RP-HPLC.METHODS The chromatographic conditions included Shimpack CLC ODS column and the mobile phase consisting of a mixture of acetonitrile-0.1% phosphoric acid (15∶85).The detection wavelength was at 230 nm.RESULTS The calibration curve was linear over the concentration range of 0.02~0.12 mg for ferulic acid and 0.02~0.08 mg for paeoniflorin respectively.The correlation coefficient was r =0.997 8 and r = 0.999 9 .The average recovery of ferulic acid was 97.61% and that of paeoniflorin was 100.07%.The precision of within-day RSD was 0.98% and 0.72% respectively.CONCLUSION The determination of ferulic acid and paeoniflorin was found to be simple and accurate.

About this research paper

What this paper is about

OBJECTIVE To develop a method for the determination of ferulic acid and paeoniflorin in Xiaoyao Wan by RP-HPLC.METHODS The chromatographic conditions included Shimpack CLC ODS column and the mobile phase consisting of a mixture of acetonitrile-0.1% phosphoric acid (15∶85).The detection wavelength was at 230 nm.RESULTS The calibration curve was linear over the concentration range of 0.02~0.12 mg for ferulic acid and 0.02~0.08 mg for paeoniflorin respectively.The correlation coefficient was r =0.997 8 and r = 0.999 9 .The average recovery of ferulic acid was 97.61% and that of paeoniflorin was 100.07%.The precision of within-day RSD was 0.98% and 0.72% respectively.CONCLUSION The determination of ferulic acid and paeoniflorin was found to be simple and accurate.

Why it matters

A significance statement is not available in the OpenAlex record.

Key contribution

A contribution statement is not available in the OpenAlex record.

Method / approach

Method details are not available in the OpenAlex metadata.

Main findings

Findings are not separately available in the OpenAlex metadata.

Limitations

Limitations are not available in the OpenAlex metadata.

Applications

Application details are not available in the OpenAlex metadata.

Available abstract

OBJECTIVE To develop a method for the determination of ferulic acid and paeoniflorin in Xiaoyao Wan by RP-HPLC.METHODS The chromatographic conditions included Shimpack CLC ODS column and the mobile phase consisting of a mixture of acetonitrile-0.1% phosphoric acid (15∶85).The detection wavelength was at 230 nm.RESULTS The calibration curve was linear over the concentration range of 0.02~0.12 mg for ferulic acid and 0.02~0.08 mg for paeoniflorin respectively.The correlation coefficient was r =0.997 8 and r = 0.999 9 .The average recovery of ferulic acid was 97.61% and that of paeoniflorin was 100.07%.The precision of within-day RSD was 0.98% and 0.72% respectively.CONCLUSION The determination of ferulic acid and paeoniflorin was found to be simple and accurate.

Key concepts: Paeoniflorin, Ferulic acid, Chromatography, Phosphoric acid, High-performance liquid chromatography, Chemistry, Calibration curve, Acetonitrile

Related papers

Back to paper searchBrowse research topicsOriginal source
Determination of ferulic acid and paeoniflorin in Xiaoyao Wan by RP-HPLC — Research Paper | ScholarLens